EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Placement-Dependent Accuracy of a Smartphone-Based Sensor Application Compared to an Accelerometer-Based System for Measuring Physical Activity in Healthy Adults: A Validation Study

Mette Garval iD, Louise Pedersen iD, Lars M Pedersen, Ane Kathrine W D J Nielsen, David H Christiansen iD, Jeppe Lange iD, Stefan Wagner iD

Sensors · 2026

DOI: 10.3390/s26072033 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Sensors, 2026. Verfasst von Mette Garval und 6 weiteren Autor:innen. Beteiligte Einrichtung: Elective Surgery Center, University Clinic for Interdisciplinary Orthopaedic Pathways, Regional Hospital Central Jutland, Falkevej 1, 8600 Silkeborg,…. Hauptthemen laut MEDLINE: Smartphone, Accelerometry, Exercise, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurately monitoring physical activity, including stationary cycling on an exercise bike, is important in managing chronic diseases and rehabilitation after lower limb surgery. This study aimed to validate a new smartphone-based sensor application (the BeSAFE+) for activity recognition and step counting across five phone placements, using the SENS Motion® system as a reference standard, and observed activity time as ground truth. In a laboratory-based study, 20 participants performed walking, brisk walking, running, high- and low-intensity cycling, sitting, standing, and lying activities while carrying five smartphones placed in the front and back trouser pockets, a backpack, a running armband, and a fanny pack, and wearing the activity tracker. The front pocket placement had the most accurate classification during cycling activities (89–93%) versus SENS Motion® (96–98%). For other activities, the highest overall classification accuracy was achieved with the phone in the back pocket. Overall, the SENS Motion® activity tracker demonstrated higher classification accuracy than most smartphone placements across all activities, except for running. Nevertheless, several smartphone placements and Application Programming Interface (API) approaches achieved activity recognition and step count estimates that were not significantly different from the SENS Motion® activity tracker, indicating that smartphone-based activity recognition can be valid under specific conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneAccelerometryExerciseBiosensing TechniquesHumansAdultFemaleMaleWalking

Stichwörter der Autor:innen

accelerometryactivity recognitionmeasurement accuracysmartphone-based sensorsvalidation studywearable sensors

Autor:innen und Institutionen

  • Elective Surgery Center, University Clinic for Interdisciplinary Orthopaedic Pathways, Regional Hospital Central Jutland, Falkevej 1, 8600 Silkeborg, Denmark.
  • Department of Clinical Medicine, Aarhus University, Vennelyst Boulevard 4, 8000 Aarhus, Denmark.
  • Department of Electrical and Computer Engineering, Aarhus University, Finlandsgade 22, 8200 Aarhus, Denmark.
  • Department of Orthopaedic Surgery, Regional Hospital Horsens, Sundvej 30, 8700 Horsens, Denmark.

ORCID-Profile: Mette Garval, Louise Pedersen, David H Christiansen, Jeppe Lange, Stefan Wagner

Förderung

  • European Union

Zitieren

APA

Garval, M., Pedersen, L., Pedersen, L. M., Nielsen, A. K. W. D. J., Christiansen, D. H., Lange, J., & Wagner, S. (2026). Placement-Dependent Accuracy of a Smartphone-Based Sensor Application Compared to an Accelerometer-Based System for Measuring Physical Activity in Healthy Adults: A Validation Study. Sensors. https://doi.org/10.3390/s26072033

Vancouver

Garval M, Pedersen L, Pedersen LM, Nielsen AKWDJ, Christiansen DH, Lange J, et al. Placement-Dependent Accuracy of a Smartphone-Based Sensor Application Compared to an Accelerometer-Based System for Measuring Physical Activity in Healthy Adults: A Validation Study. Sensors. 2026. doi:10.3390/s26072033

BibTeX
@article{Garval2026,
  author = {Garval, Mette and Pedersen, Louise and Pedersen, Lars M and Nielsen, Ane Kathrine W D J and Christiansen, David H and Lange, Jeppe and Wagner, Stefan},
  title = {Placement-Dependent Accuracy of a Smartphone-Based Sensor Application Compared to an Accelerometer-Based System for Measuring Physical Activity in Healthy Adults: A Validation Study},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26072033}
}
Kostenlos starten →