Placement-Dependent Accuracy of a Smartphone-Based Sensor Application Compared to an Accelerometer-Based System for Measuring Physical Activity in Healthy Adults: A Validation Study
Sensors · 2026
DOI: 10.3390/s26072033 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Sensors, 2026. Verfasst von Mette Garval und 6 weiteren Autor:innen. Beteiligte Einrichtung: Elective Surgery Center, University Clinic for Interdisciplinary Orthopaedic Pathways, Regional Hospital Central Jutland, Falkevej 1, 8600 Silkeborg,…. Hauptthemen laut MEDLINE: Smartphone, Accelerometry, Exercise, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union.
Abstract (Originalsprache)
Accurately monitoring physical activity, including stationary cycling on an exercise bike, is important in managing chronic diseases and rehabilitation after lower limb surgery. This study aimed to validate a new smartphone-based sensor application (the BeSAFE+) for activity recognition and step counting across five phone placements, using the SENS Motion® system as a reference standard, and observed activity time as ground truth. In a laboratory-based study, 20 participants performed walking, brisk walking, running, high- and low-intensity cycling, sitting, standing, and lying activities while carrying five smartphones placed in the front and back trouser pockets, a backpack, a running armband, and a fanny pack, and wearing the activity tracker. The front pocket placement had the most accurate classification during cycling activities (89–93%) versus SENS Motion® (96–98%). For other activities, the highest overall classification accuracy was achieved with the phone in the back pocket. Overall, the SENS Motion® activity tracker demonstrated higher classification accuracy than most smartphone placements across all activities, except for running. Nevertheless, several smartphone placements and Application Programming Interface (API) approaches achieved activity recognition and step count estimates that were not significantly different from the SENS Motion® activity tracker, indicating that smartphone-based activity recognition can be valid under specific conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Elective Surgery Center, University Clinic for Interdisciplinary Orthopaedic Pathways, Regional Hospital Central Jutland, Falkevej 1, 8600 Silkeborg, Denmark.
- Department of Clinical Medicine, Aarhus University, Vennelyst Boulevard 4, 8000 Aarhus, Denmark.
- Department of Electrical and Computer Engineering, Aarhus University, Finlandsgade 22, 8200 Aarhus, Denmark.
- Department of Orthopaedic Surgery, Regional Hospital Horsens, Sundvej 30, 8700 Horsens, Denmark.
ORCID-Profile: Mette Garval, Louise Pedersen, David H Christiansen, Jeppe Lange, Stefan Wagner
Förderung
- European Union
Zitieren
APA
Garval, M., Pedersen, L., Pedersen, L. M., Nielsen, A. K. W. D. J., Christiansen, D. H., Lange, J., & Wagner, S. (2026). Placement-Dependent Accuracy of a Smartphone-Based Sensor Application Compared to an Accelerometer-Based System for Measuring Physical Activity in Healthy Adults: A Validation Study. Sensors. https://doi.org/10.3390/s26072033
Vancouver
Garval M, Pedersen L, Pedersen LM, Nielsen AKWDJ, Christiansen DH, Lange J, et al. Placement-Dependent Accuracy of a Smartphone-Based Sensor Application Compared to an Accelerometer-Based System for Measuring Physical Activity in Healthy Adults: A Validation Study. Sensors. 2026. doi:10.3390/s26072033
BibTeX
@article{Garval2026,
author = {Garval, Mette and Pedersen, Louise and Pedersen, Lars M and Nielsen, Ane Kathrine W D J and Christiansen, David H and Lange, Jeppe and Wagner, Stefan},
title = {Placement-Dependent Accuracy of a Smartphone-Based Sensor Application Compared to an Accelerometer-Based System for Measuring Physical Activity in Healthy Adults: A Validation Study},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26072033}
}
EUVIMED