Data-Driven Parameter Identification of Synchronous Generators: A Three-Stage Framework with State Consistency and Grid Decoupling
Sensors · 24.03.2026 · 26 (7) · 2024
DOI: 10.3390/s26072024 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 24.03.2026. Verfasst von Rasool Peykarporsan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Electronic Engineering, Auckland University of Technology, Auckland 1010, New Zealand. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Business, Innovation and Employment, MBIE https://ror.org/02jtq1b51.
Abstract (Originalsprache)
As modern power systems grow increasingly complex, there is a pressing need for stability analysis methods capable of handling nonlinear dynamics while providing physically meaningful and reliable stability indices. Port-Hamiltonian (PH) frameworks have emerged as strong candidates in this regard, offering inherently stable formulations, energy-consistent representations, and modular plug-and-play scalability. However, the practical deployment of PH-based stability analysis remains hindered by the absence of reliable, high-fidelity parameter identification methods that rely on sensor measurements to capture system dynamics while remaining compatible with PH model structures. This paper addresses that gap by proposing a comprehensive three-stage data-driven identification framework for PH modeling of synchronous generators—the central dynamic component of any power system. While the IEEE Standard 115 provides established procedures for transient parameter identification, it exhibits fundamental limitations when applied to PH modeling, including single-scenario identifiability constraints, noise-sensitive derivative-based formulations that amplify sensor measurement errors, and the inability to decouple generator-internal damping from grid contributions. The proposed framework resolves these limitations through multi-scenario excitation using sensor-acquired voltage and current signals, derivative-free state consistency optimization, and physics-based regularization that enforces PH structure preservation. Complete identification of eight key parameters (H, D, Xd, Xq, Xd′, Xq′, Tdo′, Tqo′) is achieved with errors ranging from 1.26% to 9.10%, and validation confirms RMS rotor angle errors below 1.2° and speed errors below 0.15%, demonstrating suitability for transient stability analysis, passivity-based control design, and oscillation damping assessment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical and Electronic Engineering, Auckland University of Technology, Auckland 1010, New Zealand.
ORCID-Profile: Rasool Peykarporsan, Tharuka Govinda Waduge, Tek Tjing Lie
Förderung
- Ministry of Business, Innovation and Employment
- MBIE https://ror.org/02jtq1b51
Zitieren
APA
Peykarporsan, R., Govinda Waduge, T., Lie, T. T., & Stommel, M. (2026). Data-Driven Parameter Identification of Synchronous Generators: A Three-Stage Framework with State Consistency and Grid Decoupling. Sensors, 26(7), 2024. https://doi.org/10.3390/s26072024
Vancouver
Peykarporsan R, Govinda Waduge T, Lie TT, Stommel M. Data-Driven Parameter Identification of Synchronous Generators: A Three-Stage Framework with State Consistency and Grid Decoupling. Sensors. 2026;26(7):2024. doi:10.3390/s26072024
BibTeX
@article{Peykarporsan2026,
author = {Peykarporsan, Rasool and Govinda Waduge, Tharuka and Lie, Tek Tjing and Stommel, Martin},
title = {Data-Driven Parameter Identification of Synchronous Generators: A Three-Stage Framework with State Consistency and Grid Decoupling},
journal = {Sensors},
year = {2026},
volume = {26},
number = {7},
pages = {2024},
doi = {10.3390/s26072024}
}