EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development and Phantom Validation of a Small-Form-Factor SWIR Emitter Probe for Hydration-Sensitive Spatial-Ratio Measurements in Gelatin–Intralipid Phantoms

Georgei Farouq, Devang Vyas iD, Amir Tofghi Zavareh iD

Sensors · 24.03.2026 · 26 (7) · 2020

DOI: 10.3390/s26072020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 24.03.2026. Verfasst von Georgei Farouq und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering Technology and Industrial Distribution, Texas A&M University, College Station, TX 77843, USA. Hauptthemen laut MEDLINE: Phantoms, Imaging, Gelatin, Water. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-invasive assessment of tissue water content is clinically relevant for edema detection, fluid management, and monitoring of local inflammation. In the short-wave infrared (SWIR), water exhibits strong absorption near 1450 nm with a secondary band near 1650 nm, enabling hydration-sensitive reflectance measurements. However, many SWIR systems rely on spectrometers or high-power broadband sources, limiting translation to compact or wearable platforms. We present a compact SWIR diffuse-reflectance probe built from small-form-factor components using four discrete LEDs (1450 nm and 1650 nm) and a single photodetector to acquire spatially resolved measurements at two source–detector separations (4.5 mm and 7 mm). Probe-geometry-matched Monte Carlo simulations were used to generate lookup tables relating reduced scattering to same-wavelength spatial ratios. A diffusion-based forward model was then used to perform a calibration-anchored water-fraction consistency analysis. Eight gelatin–Intralipid phantoms spanning two scattering conditions and formulation-defined water fractions were evaluated. Spatial-ratio signatures were repeatable and monotonic with nominal water fraction, yielding a mean absolute percent error of 1.55% and a maximum absolute percent error of 3.33% under absorption-consistent conditions. These results demonstrate the feasibility of compact SWIR ratio sensing for controlled hydration changes in tissue-mimicking phantoms and provide a modeling framework for future extension to unknown or in vivo samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingGelatinWaterMonte Carlo MethodEmulsionsSpectrophotometry, Infrared

Stichwörter der Autor:innen

Monte Carlo lookup tablesdiffuse reflectancegelatin–Intralipid phantomhydration sensingshort-wave infrared spectroscopy (SWIRS)small-form-factor sensorspatially resolved spectroscopy

Substanzen

GelatinWaterEmulsions

Autor:innen und Institutionen

  • Department of Engineering Technology and Industrial Distribution, Texas A&M University, College Station, TX 77843, USA.
  • Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
  • Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843, USA.

ORCID-Profile: Devang Vyas, Amir Tofghi Zavareh

Zitieren

APA

Farouq, G., Vyas, D., & Tofghi Zavareh, A. (2026). Development and Phantom Validation of a Small-Form-Factor SWIR Emitter Probe for Hydration-Sensitive Spatial-Ratio Measurements in Gelatin–Intralipid Phantoms. Sensors, 26(7), 2020. https://doi.org/10.3390/s26072020

Vancouver

Farouq G, Vyas D, Tofghi Zavareh A. Development and Phantom Validation of a Small-Form-Factor SWIR Emitter Probe for Hydration-Sensitive Spatial-Ratio Measurements in Gelatin–Intralipid Phantoms. Sensors. 2026;26(7):2020. doi:10.3390/s26072020

BibTeX
@article{Farouq2026,
  author = {Farouq, Georgei and Vyas, Devang and Tofghi Zavareh, Amir},
  title = {Development and Phantom Validation of a Small-Form-Factor SWIR Emitter Probe for Hydration-Sensitive Spatial-Ratio Measurements in Gelatin–Intralipid Phantoms},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {7},
  pages = {2020},
  doi = {10.3390/s26072020}
}
Kostenlos starten →