Reconstruction of Misalignment Aberrations for Cylindrical Surfaces with Complex Parameters in Pseudo Lateral Shearing Interferometry
Sensors · 15.03.2026 · 26 (6) · 1854
DOI: 10.3390/s26061854 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 15.03.2026. Verfasst von Yuxuan Ren und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Precision Measuring Technology & Instruments, Laboratory of Micro/Nano Manufacturing Technology, Tianjin University, Tianjin …. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National key research and development program of China.
Abstract (Originalsprache)
Cylindrical surfaces with complex parameters (CSCPs) have off-axis and aspheric properties. High-precision measurement of cylindrical surfaces is a key research focus in optical metrology. Two-dimensional pseudo lateral shearing interferometry (2DPLSI) enables non-null generalized interferometry for cylindrical surfaces. However, due to the non-rotational symmetry of cylindrical surfaces with complex parameters, measuring them using two-dimensional pseudo lateral shearing interferometry inevitably introduces misalignment aberrations, degrading the accuracy of cylindrical surface reconstruction. To address this issue, we propose a novel non-null testing method: the cylindrical surface is translated in the orthogonal directions to carry out the shearing process, and wavefront errors are eliminated through second-order differencing. Furthermore, a reconstruction algorithm in one direction is proposed. Using only the partial derivative in the x direction, the wavefront error of misalignment aberrations can be reconstructed, enabling high-precision recovery of the cylindrical surface. Experimental results using a Fizeau interferometer demonstrate that the proposed method effectively reconstructs misalignment aberrations. The reconstructed cylindrical surface achieves a peak-to-valley (PV) value of 0.45λ (λ = 632.8 nm) and a root-mean-square (RMS) value of 0.12λ, comparable to the 0.37λ PV and 0.09λ RMS obtained via null testing. The repeatability of the proposed method is superior to λ/1000 RMS.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Precision Measuring Technology & Instruments, Laboratory of Micro/Nano Manufacturing Technology, Tianjin University, Tianjin 300072, China.
- Sichuan Precision and Ultra-Precision Machining Engineering Technology Center, Chengdu 610200, China.
ORCID-Profile: Yang Chen
Förderung
- National Natural Science Foundation of China
- National key research and development program of China
Zitieren
APA
Ren, Y., Luo, W., Chen, Y., Zhao, L., He, L., Zhang, S., Hai, K., Zhang, X., & Zang, Z. (2026). Reconstruction of Misalignment Aberrations for Cylindrical Surfaces with Complex Parameters in Pseudo Lateral Shearing Interferometry. Sensors, 26(6), 1854. https://doi.org/10.3390/s26061854
Vancouver
Ren Y, Luo W, Chen Y, Zhao L, He L, Zhang S, et al. Reconstruction of Misalignment Aberrations for Cylindrical Surfaces with Complex Parameters in Pseudo Lateral Shearing Interferometry. Sensors. 2026;26(6):1854. doi:10.3390/s26061854
BibTeX
@article{Ren2026,
author = {Ren, Yuxuan and Luo, Weizhou and Chen, Yang and Zhao, Le and He, Liuqing and Zhang, Siqi and Hai, Kuo and Zhang, Xiaodong and Zang, Zhongming},
title = {Reconstruction of Misalignment Aberrations for Cylindrical Surfaces with Complex Parameters in Pseudo Lateral Shearing Interferometry},
journal = {Sensors},
year = {2026},
volume = {26},
number = {6},
pages = {1854},
doi = {10.3390/s26061854}
}
EUVIMED