EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Residual Amplitude Modulation Noise Suppression Method Based on Multi-Harmonic Component Decoupling

Qiwu Luo, Hang Su, Yibo Wang, Chunhua Yang

Sensors · 14.03.2026 · 26 (6) · 1841

DOI: 10.3390/s26061841 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 14.03.2026. Verfasst von Qiwu Luo und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Automation, Central South University, Changsha 410083, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wavelength modulation spectroscopy (WMS) is a representative implementation of tunable diode laser absorption spectroscopy (TDLAS), enabling reliable gas component analysis with concentration-related information derived from harmonic component extraction, while offering enhanced noise immunity for trace gas sensing in open environments. However, due to the strong coupling between laser wavelength and intensity, wavelength modulation inevitably introduces residual amplitude modulation (RAM), which significantly degrades measurement accuracy. To address this issue, this study introduces a RAM suppression algorithm based on multiple harmonic component decoupling (MHCD), using the second-harmonic lateral peak inclination angle (LPIA) as a characteristic indicator. Unit harmonic operators for the first, second, and third harmonics are designed, and an original harmonic reconstruction model is established via linear superposition of harmonic components. The optimal harmonic component ratio is determined at the composite operator with the maximum cross-correlation coefficient, and RAM noise is eliminated through a multi-harmonic decoupling matrix. Repetitive measurements on 22 mm pharmaceutical vials with 4% oxygen concentration demonstrate that MHCD reduces the second-harmonic LPIA from 18.07° to 8.56°. Concentration discrimination experiments conducted on seven groups of 22 mm vials with 2% concentration steps (0–12%) show that MHCD increases the true positive rate by 6–11% and decreases the false positive rate by 4–9%, confirming its effectiveness for pharmaceutical online inspection applications.

Schlagwörter

Stichwörter der Autor:innen

lateral peak inclination anglemultiple harmonic component decouplingresidual amplitude modulation

Autor:innen und Institutionen

  • School of Automation, Central South University, Changsha 410083, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Luo, Q., Su, H., Wang, Y., & Yang, C. (2026). A Residual Amplitude Modulation Noise Suppression Method Based on Multi-Harmonic Component Decoupling. Sensors, 26(6), 1841. https://doi.org/10.3390/s26061841

Vancouver

Luo Q, Su H, Wang Y, Yang C. A Residual Amplitude Modulation Noise Suppression Method Based on Multi-Harmonic Component Decoupling. Sensors. 2026;26(6):1841. doi:10.3390/s26061841

BibTeX
@article{Luo2026,
  author = {Luo, Qiwu and Su, Hang and Wang, Yibo and Yang, Chunhua},
  title = {A Residual Amplitude Modulation Noise Suppression Method Based on Multi-Harmonic Component Decoupling},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {6},
  pages = {1841},
  doi = {10.3390/s26061841}
}
Kostenlos starten →