EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Near-Wellbore Fracture Diagnosis via Strain Decoupling from Integrated In-Well LF-DAS and DTS Data

Jiayi Song, Weibo Sui, Huan Guo, Jiwen Li

Sensors · 13.03.2026 · 26 (6) · 1813

DOI: 10.3390/s26061813 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 13.03.2026. Verfasst von Jiayi Song und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Petroleum Engineering, China University of Petroleum (Beijing), Beijing 102249, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Natural Science Fund of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The low-frequency distributed acoustic sensing (LF-DAS) data acquired through fiber-optic cables cemented behind the fracturing well casing can dynamically capture the hydraulic fracturing process. After removing the thermal effect, the LF-DAS data can reveal the strain evolution induced by the initiation of hydraulic fractures. This paper presented an improved strain–temperature decoupling method for LF-DAS measurements based on joint LF-DAS/distributed temperature sensing (DTS) monitoring. The decoupling method was based on strain change and temperature change pre-processed from the raw DAS and DTS data to avoid the enhancement of DTS data noise. The moving window function method and the image processing parameter cosine similarity was introduced to cope with the differences in temporal and spatial resolution between LF-DAS and DTS data. The region significantly affected by temperature change could be identified automatically and the mechanical strain change could be extracted. The tensile strain response generally reached a local peak at perforation clusters and increased significantly at those with dominant fracture fluid inflow. By analyzing the evolution of strain profile during fracturing, the effectiveness of multi-cluster fracture initiation and fracture temporary plugging could be evaluated.

Schlagwörter

Stichwörter der Autor:innen

distributed acoustic sensingfracture diagnosisin-well LF-DAS

Autor:innen und Institutionen

  • College of Petroleum Engineering, China University of Petroleum (Beijing), Beijing 102249, China.

Förderung

  • National Natural Science Foundation of China
  • National Natural Science Fund of China

Zitieren

APA

Song, J., Sui, W., Guo, H., & Li, J. (2026). Near-Wellbore Fracture Diagnosis via Strain Decoupling from Integrated In-Well LF-DAS and DTS Data. Sensors, 26(6), 1813. https://doi.org/10.3390/s26061813

Vancouver

Song J, Sui W, Guo H, Li J. Near-Wellbore Fracture Diagnosis via Strain Decoupling from Integrated In-Well LF-DAS and DTS Data. Sensors. 2026;26(6):1813. doi:10.3390/s26061813

BibTeX
@article{Song2026,
  author = {Song, Jiayi and Sui, Weibo and Guo, Huan and Li, Jiwen},
  title = {Near-Wellbore Fracture Diagnosis via Strain Decoupling from Integrated In-Well LF-DAS and DTS Data},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {6},
  pages = {1813},
  doi = {10.3390/s26061813}
}
Kostenlos starten →