EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Data-Constrained and Physics-Guided Conditional Diffusion Model for Electrical Impedance Tomography Image Reconstruction

Xiaolei Zhang, Zhou Rong

Sensors · 09.03.2026 · 26 (5) · 1728

DOI: 10.3390/s26051728 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 09.03.2026. Verfasst von Xiaolei Zhang und 1 weiteren Autor:innen. Beteiligte Einrichtung: College of Automation, Nanjing University of Posts and Telecommunications, Nanjing 210023, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrical impedance tomography (EIT) provides noninvasive, high-temporal-resolution imaging for medical and industrial applications. However, accurate image reconstruction remains challenging due to the severe ill-posedness and nonlinearity of the inverse problem, as well as the limited robustness of existing single-source learning-based methods in real measurement scenarios. To address these limitations, a data-constrained and physics-guided Multi-Source Conditional Diffusion Model (MS-CDM) is proposed for EIT image reconstruction. Unlike conventional conditional diffusion methods that rely on a single measurement or an image prior, MS-CDM utilizes boundary voltage measurements as data-driven constraints and incorporates coarse reconstructions as physics-guided structural priors. This multi-source conditioning strategy provides complementary guidance during the reverse diffusion process, enabling balanced recovery of fine boundary details and global topological consistency. To support this framework, a Hybrid Swin–Mamba Denoising U-Net is developed, combining hierarchical window-based self-attention for local spatial modeling with bidirectional state-space modeling for efficient global dependency capture. Extensive experiments on simulated datasets and three real EIT experimental platforms demonstrate that MS-CDM consistently outperforms state-of-the-art numerical, supervised, and diffusion-based methods in terms of reconstruction accuracy, structural consistency, and noise robustness. Moreover, the proposed model exhibits robust cross-system applicability without system-specific retraining under multi-protocol training, highlighting its practical applicability in diverse real-world EIT scenarios.

Schlagwörter

Stichwörter der Autor:innen

conditional diffusion modeldeep learningelectrical impedance tomographyimage reconstructionmulti-source information fusion

Autor:innen und Institutionen

  • College of Automation, Nanjing University of Posts and Telecommunications, Nanjing 210023, China.

Zitieren

APA

Zhang, X., & Rong, Z. (2026). A Data-Constrained and Physics-Guided Conditional Diffusion Model for Electrical Impedance Tomography Image Reconstruction. Sensors, 26(5), 1728. https://doi.org/10.3390/s26051728

Vancouver

Zhang X, Rong Z. A Data-Constrained and Physics-Guided Conditional Diffusion Model for Electrical Impedance Tomography Image Reconstruction. Sensors. 2026;26(5):1728. doi:10.3390/s26051728

BibTeX
@article{Zhang2026,
  author = {Zhang, Xiaolei and Rong, Zhou},
  title = {A Data-Constrained and Physics-Guided Conditional Diffusion Model for Electrical Impedance Tomography Image Reconstruction},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {5},
  pages = {1728},
  doi = {10.3390/s26051728}
}
Kostenlos starten →