EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Wide-Field Oxygen Permeability Measurement of Contact Lenses Using a Modified Polarographic Electrode Cell

Wen-Hong Tong iD, Jing Liu iD, Jae-Yeon Pyo iD, Ki-Choong Mah iD, Seung-Jin Oh iD, Jae-Young Jang iD

Sensors · 09.03.2026 · 26 (5) · 1725

DOI: 10.3390/s26051725 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 09.03.2026. Verfasst von Wen-Hong Tong und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry, Eulji University, 553 Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Republic of Korea. Hauptthemen laut MEDLINE: Oxygen, Polarography, Contact Lenses. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea (NRF).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oxygen permeability (Dk) is a key parameter for evaluating the ability of contact lenses to supply oxygen to the cornea. Although the polarographic method has been standardized as a reference technique for Dk measurement, conventional polarographic electrode cells are limited to a narrow central measurement area of approximately 4 mm in diameter, which may not adequately represent oxygen transport under actual wearing conditions. In this study, a modified polarographic electrode cell enabling wide-field oxygen permeability measurement over an expanded central area with a diameter of 11 mm was developed and evaluated under ISO 18369 measurement conditions. The performance of the proposed system was evaluated by comparing its accuracy, repeatability, and relative error with those of a conventional polarographic electrode cell using plano hydrogel contact lens samples with different uniform thicknesses. The Dk values obtained using the modified measurement cell did not show a statistically significant difference compared to those measured with the conventional measurement cell (t = 2.682, p = 0.055), and the relative error between the two systems was 1.93%, meeting the ISO acceptance criteria for the development of a new testing method. These results demonstrate that wide-field Dk measurement can be achieved without compromising reliability, providing a more representative and ISO-compliant approach for contact lens oxygen permeability evaluation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OxygenPolarographyContact LensesElectrodesPermeabilityHumansReproducibility of Results

Stichwörter der Autor:innen

ISO 18369contact lensescorneal oxygenationoxygen permeabilityoxygen transmissibilitypolarographic electrode cellwide-field measurement

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Optometry, Eulji University, 553 Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Republic of Korea.
  • International College of Optometry, Jining Polytechnic, 77 Jinyu Road, Jining 272007, China.
  • Olens Gangnam Daechi Optical Center, 102-1, 2936 Nambusunhwan-ro, Gangnam-gu, Seoul 06291, Republic of Korea.
  • Korean Vision Care Research Institute, 12-17, 14 Gosanja-ro, Seongdong-gu, Seoul 04750, Republic of Korea.
  • Luce Vision Center, B1, 401 Teheran-ro, Gangnam-gu, Seoul 06162, Republic of Korea.
  • Department of Optometry, Jeonbuk Science College, 117 Chungjeong-ro, Jeongeup-si 56204, Republic of Korea.

ORCID-Profile: Wen-Hong Tong, Jing Liu, Jae-Yeon Pyo, Ki-Choong Mah, Seung-Jin Oh, Jae-Young Jang

Förderung

  • National Research Foundation of Korea (NRF)

Zitieren

APA

Tong, W. H., Liu, J., Pyo, J. Y., Mah, K. C., Oh, S. J., & Jang, J. Y. (2026). Wide-Field Oxygen Permeability Measurement of Contact Lenses Using a Modified Polarographic Electrode Cell. Sensors, 26(5), 1725. https://doi.org/10.3390/s26051725

Vancouver

Tong WH, Liu J, Pyo JY, Mah KC, Oh SJ, Jang JY. Wide-Field Oxygen Permeability Measurement of Contact Lenses Using a Modified Polarographic Electrode Cell. Sensors. 2026;26(5):1725. doi:10.3390/s26051725

BibTeX
@article{Tong2026,
  author = {Tong, Wen-Hong and Liu, Jing and Pyo, Jae-Yeon and Mah, Ki-Choong and Oh, Seung-Jin and Jang, Jae-Young},
  title = {Wide-Field Oxygen Permeability Measurement of Contact Lenses Using a Modified Polarographic Electrode Cell},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {5},
  pages = {1725},
  doi = {10.3390/s26051725}
}
Kostenlos starten →