An Efficient Finger Vein Recognition Method Based on Improved Lightweight MobileNet
Sensors · 05.03.2026 · 26 (5) · 1634
DOI: 10.3390/s26051634 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 05.03.2026. Verfasst von Xuhui Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Measurement and Control Technology and Communication Engineering, Harbin University of Science and Technology, Harbin 150080, China. Hauptthemen laut MEDLINE: Fingers, Veins, Biometric Identification. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The National Key Research and Development Program of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
Finger vein recognition has emerged as a highly robust and intrinsically stable biometric technology, demonstrating great potential in identity authentication and intelligent security applications. However, conventional methods still suffer from constraints in feature representation and computational efficiency, particularly under challenging conditions such as illumination variation, pose deviation, and noise interference. To address these challenges, this study presents an efficient finger vein recognition approach based on a lightweight convolutional neural network (LCNN) architecture. The proposed framework integrates a multi-stage image preprocessing pipeline for automatic vein region detection, advanced denoising, and refined texture enhancement, which is subsequently followed by compact feature modeling within a lightweight deep network. Extensive experiments on the public Shandong University Machine Learning and Applications-Homologous Multi-Modal Traits (SDUMLA-HMT) dataset and a self-acquired Laboratory Finger-Vein (Lab-Vein) dataset validate the superiority of the proposed method, achieving recognition accuracies of 97.1% and 98.3%, respectively, surpassing existing benchmark models. Moreover, the model demonstrates notable reductions in parameter complexity and computational cost, achieving an average inference time of only 12.6 ms, which confirms its strong real-time capability and suitability for embedded deployment. Overall, the proposed approach attains a desirable trade-off between accuracy and efficiency, offering meaningful implications for the advancement of lightweight biometric recognition systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Measurement and Control Technology and Communication Engineering, Harbin University of Science and Technology, Harbin 150080, China.
- School of Electrical, Electronic and Intelligent Engineering/Department of Electrical Engineering, Harbin Cambridge University, Harbin 150069, China.
ORCID-Profile: Xuhui Zhang, Yuxi Liu, Yixin Yan, Lei Xu
Förderung
- The National Key Research and Development Program of China
- National Key Research and Development Program of China
Zitieren
APA
Zhang, X., Liu, Y., Yan, Y., Li, J., & Xu, L. (2026). An Efficient Finger Vein Recognition Method Based on Improved Lightweight MobileNet. Sensors, 26(5), 1634. https://doi.org/10.3390/s26051634
Vancouver
Zhang X, Liu Y, Yan Y, Li J, Xu L. An Efficient Finger Vein Recognition Method Based on Improved Lightweight MobileNet. Sensors. 2026;26(5):1634. doi:10.3390/s26051634
BibTeX
@article{Zhang2026,
author = {Zhang, Xuhui and Liu, Yuxi and Yan, Yixin and Li, Jiabin and Xu, Lei},
title = {An Efficient Finger Vein Recognition Method Based on Improved Lightweight MobileNet},
journal = {Sensors},
year = {2026},
volume = {26},
number = {5},
pages = {1634},
doi = {10.3390/s26051634}
}
EUVIMED