EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accurate Lens-Distortion Measurement Through Detector Nyquist Sampling

Yongqiang Yang, Zhiyi Wang iD, Junlin Li, Zhongming Li, Jianlin Lv, Min Zhao, Yanfu Tang, Jianli Wang

Sensors · 01.03.2026 · 26 (5) · 1550

DOI: 10.3390/s26051550 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 01.03.2026. Verfasst von Yongqiang Yang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research on accuracy improvement mechanism and path of heavy load six degrees of freedom adjustment platform for Large Digital Survey Telescope.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Distortion is a key parameter affecting the imaging performance of lenses. In this study, we propose a testing method based on detector Nyquist sampling of image data to achieve high-precision measurements of the distortion distribution of lenses. The distribution patterns of distortions in horizontal and vertical directions can be obtained by analyzing the distribution patterns of Moiré fringes in images under Nyquist sampling conditions and using phase-shift algorithms. The distortion-distribution characteristics of the lens are then calculated using distortion formulas. This method is characterized by high testing accuracy and sampling resolution. The image-plane distortion distribution exhibited a consistent linear trend when the object-plane position varied within a limited spatial range. Furthermore, the proposed method achieved a magnification deviation factor repeatability accuracy of approximately ±108 nm/cm and third-order distortion-measurement accuracy of approximately ±108 nm/cm3. This method enables a high-precision distortion evaluation of conventional industrial imaging lenses.

Schlagwörter

Stichwörter der Autor:innen

Nyquist samplingdistortionfringe patternphase shift

Autor:innen und Institutionen

  • Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • University of Chinese Academy of Sciences, Beijing 100049, China.

ORCID-Profile: Zhiyi Wang

Förderung

  • Research on accuracy improvement mechanism and path of heavy load six degrees of freedom adjustment platform for Large Digital Survey Telescope

Zitieren

APA

Yang, Y., Wang, Z., Li, J., Li, Z., Lv, J., Zhao, M., Tang, Y., & Wang, J. (2026). Accurate Lens-Distortion Measurement Through Detector Nyquist Sampling. Sensors, 26(5), 1550. https://doi.org/10.3390/s26051550

Vancouver

Yang Y, Wang Z, Li J, Li Z, Lv J, Zhao M, et al. Accurate Lens-Distortion Measurement Through Detector Nyquist Sampling. Sensors. 2026;26(5):1550. doi:10.3390/s26051550

BibTeX
@article{Yang2026,
  author = {Yang, Yongqiang and Wang, Zhiyi and Li, Junlin and Li, Zhongming and Lv, Jianlin and Zhao, Min and Tang, Yanfu and Wang, Jianli},
  title = {Accurate Lens-Distortion Measurement Through Detector Nyquist Sampling},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {5},
  pages = {1550},
  doi = {10.3390/s26051550}
}