Characterization of a Time Transfer Channel Between a Narrow-Band Transponder on a GEO Satellite and a Ground-Based Station
Sensors · 27.02.2026 · 26 (5) · 1515
DOI: 10.3390/s26051515 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.02.2026. Verfasst von Ferran Valdes Crespi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Fraunhofer Institute for High Frequency Physics and Radar Techniques (FHR), Fraunhoferstr. 20, 53343 Wachtberg, Germany. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fraunhofer Institute Internal Programs - Discover, Fraunhofer Internal Programs.
Abstract (Originalsprache)
Time synchronization and positioning of bistatic radar transceivers is required to coordinate and meaningfully merge the measurements made between them. It simultaneously allows the radar transceivers to change their position throughout time. Despite their acknowledged vulnerabilities, Global Navigation Satellite Systems (GNSSs) are the preferred source for Positioning, Navigation and Timing (PNT) services. Because of these vulnerabilities however, research on possible signal sources to obtain alternative positioning, navigation and timing (A-PNT) is of interest. This present work proposes the use of a narrow-band transponder installed on a geostationary (GEO) satellite to be used as one anchor for a future time transfer. A channel calibration is made between the transceiver station and the chosen satellite. Diverse models are used to estimate the channel effects throughout the signal propagation path, estimate the time delay, and correct the measurements, accordingly. The available channel bandwidth on the proposed satellite is 2.7 kHz, limiting the accuracy of the time measurements. After integration of multiple pulses, a time accuracy of approximately 1 μs is obtained. The range measurements are compared against satellite positions propagated from publicly available two-line element sets (TLEs). The obtained results suggest that, after calibration, the expected accuracy and a good repeatability is obtained. Thus, making the QO-100 satellite a suitable anchor for the proposed technique.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Fraunhofer Institute for High Frequency Physics and Radar Techniques (FHR), Fraunhoferstr. 20, 53343 Wachtberg, Germany.
- Lehrstuhl Radar-Systemtechnik, Institut für Hochfrequenztechnik (IHF), RWTH Aachen University, 52062 Aachen, Germany.
ORCID-Profile: Ferran Valdes Crespi, Pol Barrull Costa, Angel Slavov, Peter Knott
Förderung
- Fraunhofer Institute Internal Programs - Discover
- Fraunhofer Internal Programs
Zitieren
APA
Valdes Crespi, F., Barrull Costa, P., Slavov, A., Weiß, M., & Knott, P. (2026). Characterization of a Time Transfer Channel Between a Narrow-Band Transponder on a GEO Satellite and a Ground-Based Station. Sensors, 26(5), 1515. https://doi.org/10.3390/s26051515
Vancouver
Valdes Crespi F, Barrull Costa P, Slavov A, Weiß M, Knott P. Characterization of a Time Transfer Channel Between a Narrow-Band Transponder on a GEO Satellite and a Ground-Based Station. Sensors. 2026;26(5):1515. doi:10.3390/s26051515
BibTeX
@article{ValdesCrespi2026,
author = {Valdes Crespi, Ferran and Barrull Costa, Pol and Slavov, Angel and Weiß, Matthias and Knott, Peter},
title = {Characterization of a Time Transfer Channel Between a Narrow-Band Transponder on a GEO Satellite and a Ground-Based Station},
journal = {Sensors},
year = {2026},
volume = {26},
number = {5},
pages = {1515},
doi = {10.3390/s26051515}
}
EUVIMED