High-Precision Ultrasonic Anemometry System Based on Polyvinylidene Fluoride Piezoelectric Film and Variational Mode Decomposition-Extended Kalman Filter Joint Optimization
Sensors · 26.02.2026 · 26 (5) · 1482
DOI: 10.3390/s26051482 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 26.02.2026. Verfasst von Haodong Niu und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Measurement and Control Technology and Communication Engineering, Harbin University of Science and Technology, Harbin 150080, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, China National Basic Enhancement Program.
Abstract (Originalsprache)
Ultrasonic wind speed measurements performed in complex flow fields face challenges related to low signal-to-noise ratio (SNR) and non-stationary waveform distortion. In this study, we aim to address this issue by proposing a measurement system that employs a polyvinylidene fluoride (PVDF) piezoelectric film ultrasonic transducer integrated with a microphone (MIC). In addition, a signal processing framework is proposed based on the joint optimization of variational mode decomposition (VMD) and an extended Kalman filter (EKF) and integrating cross-correlation interpolation. By leveraging the low Q-factor and wide bandwidth characteristics of the PVDF, the system achieved omnidirectional transmission and high-fidelity reception within a compact structural design. The experimental results demonstrated that the proposed VMD-reference signal-assisted EKF method enhanced the SNR by approximately 26% and reduced the wind speed measurement error by approximately 35% compared with the conventional EKF. The proposed system exhibited superior robustness and measurement linearity across a wide wind speed range of 0–60 m/s. The proposed scheme significantly enhances the accuracy and environmental adaptability of ultrasonic wind speed measurements and provides an essential theoretical basis and engineering reference for the development of precision instruments in fields such as meteorological monitoring and wind energy assessment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Measurement and Control Technology and Communication Engineering, Harbin University of Science and Technology, Harbin 150080, China.
- China Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentations of Heilongjiang Province, Harbin 150080, China.
ORCID-Profile: Yunbo Shi
Förderung
- National Natural Science Foundation of China
- China National Basic Enhancement Program
Zitieren
APA
Niu, H., Shi, Y., Zhao, K., Liu, J., Chen, Q., & Yang, X. (2026). High-Precision Ultrasonic Anemometry System Based on Polyvinylidene Fluoride Piezoelectric Film and Variational Mode Decomposition-Extended Kalman Filter Joint Optimization. Sensors, 26(5), 1482. https://doi.org/10.3390/s26051482
Vancouver
Niu H, Shi Y, Zhao K, Liu J, Chen Q, Yang X. High-Precision Ultrasonic Anemometry System Based on Polyvinylidene Fluoride Piezoelectric Film and Variational Mode Decomposition-Extended Kalman Filter Joint Optimization. Sensors. 2026;26(5):1482. doi:10.3390/s26051482
BibTeX
@article{Niu2026,
author = {Niu, Haodong and Shi, Yunbo and Zhao, Kuo and Liu, Jinzhou and Chen, Qinglong and Yang, Xiaohui},
title = {High-Precision Ultrasonic Anemometry System Based on Polyvinylidene Fluoride Piezoelectric Film and Variational Mode Decomposition-Extended Kalman Filter Joint Optimization},
journal = {Sensors},
year = {2026},
volume = {26},
number = {5},
pages = {1482},
doi = {10.3390/s26051482}
}
EUVIMED