A High-Frequency Wearable IMU-Based System for Countermovement Jump Assessment
Sensors · 2026
DOI: 10.3390/s26051408 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Antonio Pousibet-Garrido und 6 weiteren Autor:innen. Beteiligte Einrichtung: PRIMELab, Department of Electronics and Computer Technology, Centre for Information and Communications Technologies (CITIC-UGR), University of Granad…. Hauptthemen laut MEDLINE: Wearable Electronic Devices. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Consejo Superior de Deportes (Ministerio de Cultura y Deporte).
Abstract (Originalsprache)
The countermovement jump (CMJ) is widely used to monitor neuromuscular performance in sport, but its assessment is largely dependent on force platforms, which limits their use outside the laboratory due to their cost and limited portability. This work describes the development and validation of a fully custom wearable inertial measurement unit (IMU) system for CMJ assessment. The platform is based on a single IMU placed on the lower back and sampled at 1 kHz, and includes Bluetooth Low Energy (BLE) communication together with dedicated PC and smartphone applications. A new algorithm based on the derivative of vertical acceleration was implemented to identify take-off and landing instants. The system was evaluated using 119 CMJ trials performed by 19 participants and validated against a force platform used as the criterion reference. Different acceleration thresholds were tested, with 0.2 g providing the best compromise between detection robustness and the statistical quality of the measurements, yielding a detection rate of 97.43%. Agreement analysis showed a small systematic underestimation of flight time (bias = −0.0117 s), with moderate limits of agreement across the observed range. These results indicate that the proposed system may be suitable for practical, field-based CMJ monitoring, although the observed variability relative to force-platform measurements should be considered, particularly in applications requiring individual-level decision making.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- PRIMELab, Department of Electronics and Computer Technology, Centre for Information and Communications Technologies (CITIC-UGR), University of Granada, 18071 Granada, Spain.
- Sport and Health University Research Institute (iMUDS), University of Granada, 18016 Granada, Spain.
- Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, 18011 Granada, Spain.
ORCID-Profile: Cristina Benavente, Sergio Pérez-Regalado, Miguel A Carvajal, Ignacio J Chirosa, Pablo Escobedo
Förderung
- Consejo Superior de Deportes (Ministerio de Cultura y Deporte)
Zitieren
APA
Pousibet-Garrido, A., Benavente, C., Moreno-Pérez, J. A., Pérez-Regalado, S., Carvajal, M. A., Chirosa, I. J., & Escobedo, P. (2026). A High-Frequency Wearable IMU-Based System for Countermovement Jump Assessment. Sensors. https://doi.org/10.3390/s26051408
Vancouver
Pousibet-Garrido A, Benavente C, Moreno-Pérez JA, Pérez-Regalado S, Carvajal MA, Chirosa IJ, et al. A High-Frequency Wearable IMU-Based System for Countermovement Jump Assessment. Sensors. 2026. doi:10.3390/s26051408
BibTeX
@article{PousibetGarrido2026,
author = {Pousibet-Garrido, Antonio and Benavente, Cristina and Moreno-Pérez, Juan A and Pérez-Regalado, Sergio and Carvajal, Miguel A and Chirosa, Ignacio J and Escobedo, Pablo},
title = {A High-Frequency Wearable IMU-Based System for Countermovement Jump Assessment},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26051408}
}
EUVIMED