An sEMG Denoising Method with Improved Threshold Estimation for Rapid Keystroke Tasks
Sensors · 2026
DOI: 10.3390/s26041375 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Pengze Han und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Mechanism Theory and Equipment Design, Ministry of Education, Tianjin University, Tianjin 300350, China. Hauptthemen laut MEDLINE: Electromyography. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Surface electromyography (sEMG) signals are inevitably affected by noise during acquisition, thereby degrading signal quality and analytical reliability. Most existing denoising methods combine signal decomposition with thresholding, and their performance depends on empirically set decomposition parameters and threshold estimation. However, in high-rate repetitive motions such as rapid keystrokes, sustained high-duty-cycle muscle activation biases universal-threshold noise estimation, leading to unreliable thresholds. To overcome these issues, an sEMG denoising method that integrates the Walrus Optimizer (WO) with Variational Mode Decomposition (VMD) is proposed. WO is employed to optimize key VMD parameters, including the number of modes K and the penalty factor α. Based on this method, an improved threshold estimation strategy is developed to accommodate high-duty-cycle sEMG during rapid keystrokes. It reduces thresholding-induced over-attenuation of meaningful myoelectric components. The dataset included 18 participants with sEMG recorded from six muscles during rapid keystroke tasks (10 trials per participant; 20 keystrokes per trial). Across input signal-to-noise ratios (SNRs) of 0, 5, 10, 15 dB, the proposed method achieved a median SNR improvement (ΔSNR) ranging from 2.75 to 6.65 dB and a median root-mean-square error (RMSE) reduction rate (ΔRMSE%) ranging from 27% to 53%, while maintaining spectral fidelity with a median of median frequency variation rate (ΔMDF%) below 3.48%.These results indicate that the proposed method provides an efficient and reliable solution for sEMG signal processing in rapid keystroke analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Mechanism Theory and Equipment Design, Ministry of Education, Tianjin University, Tianjin 300350, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Han, P., Ding, B., Deng, P., Wu, D., & Li, H. (2026). An sEMG Denoising Method with Improved Threshold Estimation for Rapid Keystroke Tasks. Sensors. https://doi.org/10.3390/s26041375
Vancouver
Han P, Ding B, Deng P, Wu D, Li H. An sEMG Denoising Method with Improved Threshold Estimation for Rapid Keystroke Tasks. Sensors. 2026. doi:10.3390/s26041375
BibTeX
@article{Han2026,
author = {Han, Pengze and Ding, Baihui and Deng, Penghao and Wu, Dengxiong and Li, Huilong},
title = {An sEMG Denoising Method with Improved Threshold Estimation for Rapid Keystroke Tasks},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26041375}
}
EUVIMED