Assessment of a Passive Exoskeleton for Neck and Lower Back Support: A Task Study on Muscle Activity and User Perceived Exertion
Sensors · 2026
DOI: 10.3390/s26041354 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Niromand Jasimi Zindashti und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada. Hauptthemen laut MEDLINE: Neck, Exoskeleton Device, Physical Exertion. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Natural Sciences and Engineering Research Council of Canada in partnership with Alberta Innovates.
Abstract (Originalsprache)
Musculoskeletal disorders, particularly in the neck and back, are prevalent across various professions, stemming from prolonged static postures and awkward neck flexions. This study investigated the efficacy of a passive exoskeleton, designed to alleviate musculoskeletal neck and back strain, in a simulated neck flexion task. Ten participants performed tasks involving neck flexion at angles of 15°, 30°, 45°, and 60°, both with and without the exoskeleton. Additionally, the impact of using a headlight was evaluated at a 45° neck flexion angle. Wearable electromyography sensors were used to quantify muscle activity as an indicator of neuromuscular loading, while subjective discomfort was assessed using the Rate of Perceived Exertion scale, and endurance times were recorded. The results demonstrated significant reductions in neck and lower back muscle activity (median values up to 31.0%) and perceived discomfort (median values up to 50.0%), with the most improvements at 30° and 45° neck flexion angles. Participants reported 50% higher endurance time when using the exoskeleton. Minimal benefits were observed at 15° flexion, likely due to reduced musculoskeletal demand at this angle. These findings highlight the potential of exoskeletons as an ergonomic intervention to mitigate neck and back strain in occupations where high degrees of neck flexion are prevalent.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
- EWI Works International Inc., Edmonton, AB T6E 3N8, Canada.
- Department of Electrical & Computer Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
- Department of Biomedical Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
- Glenrose Rehabilitation Hospital, Edmonton, AB T5G 0B7, Canada.
- Department of Civil and Environmental Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
ORCID-Profile: Mahdi Tavakoli, Hossein Rouhani, Ali Golabchi
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Natural Sciences and Engineering Research Council of Canada in partnership with Alberta Innovates
Zitieren
APA
Jasimi Zindashti, N., Riahi, N., Miller, L., Tavakoli, M., Rouhani, H., & Golabchi, A. (2026). Assessment of a Passive Exoskeleton for Neck and Lower Back Support: A Task Study on Muscle Activity and User Perceived Exertion. Sensors. https://doi.org/10.3390/s26041354
Vancouver
Jasimi Zindashti N, Riahi N, Miller L, Tavakoli M, Rouhani H, Golabchi A. Assessment of a Passive Exoskeleton for Neck and Lower Back Support: A Task Study on Muscle Activity and User Perceived Exertion. Sensors. 2026. doi:10.3390/s26041354
BibTeX
@article{JasimiZindashti2026,
author = {Jasimi Zindashti, Niromand and Riahi, Negar and Miller, Linda and Tavakoli, Mahdi and Rouhani, Hossein and Golabchi, Ali},
title = {Assessment of a Passive Exoskeleton for Neck and Lower Back Support: A Task Study on Muscle Activity and User Perceived Exertion},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26041354}
}
EUVIMED