EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Deep Learning for Freezing of Gait Detection: Cross-Dataset Validation Reveals Critical Deployment Gaps Between Laboratory and Daily Living Wearable Monitoring

Wei Lin, Sanjeet S Grewal

Sensors · 2026

DOI: 10.3390/s26041352 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Wei Lin und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, The 904th Hospital of the Joint Logistics Support Force of People's Liberation Army, Wuxi 214000, China. Hauptthemen laut MEDLINE: Deep Learning, Wearable Electronic Devices, Gait. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Freezing of gait (FoG) affects 38–65% of advanced Parkinson’s disease patients, yet automated detection algorithms are often validated solely on laboratory datasets. This study quantifies the critical performance gap between laboratory and real-world performance—a prerequisite for clinical deployment. Using temporal convolutional networks (TCNs), we trained models on two public datasets representing ecological extremes: a daily living dataset (Figshare; n = 35, single-sensor) and a laboratory dataset (DAPHNET; n = 10, multi-sensor). We compared five training configurations to address class imbalance. Results showed that F1-based early stopping outperformed Area Under the Curve (AUC)-based stopping by 47% (F1: 0.55 vs. 0.37, p = 0.0008). Combining multiple imbalance corrections (focal loss, weighting, sampling) paradoxically degraded precision to 33% due to a ~60-fold over-weighting of the minority class. Most importantly, cross-dataset validation revealed an 83% performance gap: laboratory F1 reached 0.9999 ± 0.0002, whereas daily living F1 dropped to 0.55 ± 0.26 (p < 0.0001), with a 1299-fold increase in variance. These findings demonstrate that laboratory success does not guarantee real-world utility. We propose that the observed gap represents a “deployment gap” reflecting the combined influence of environmental complexity, sensor constraints, and physiological variability. These results provide an empirical framework for evaluating deployment readiness of wearable FoG detection systems and offer concrete training strategy recommendations for clinical translation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningWearable Electronic DevicesGaitHumansAlgorithmsParkinson DiseaseActivities of Daily LivingMonitoring, PhysiologicLaboratories

Stichwörter der Autor:innen

Parkinson’s diseaseclass imbalanceclinical translationcross-dataset validationdeep learningfreezing of gaittemporal convolutional networkwearable sensors

Autor:innen und Institutionen

  • Department of Neurosurgery, The 904th Hospital of the Joint Logistics Support Force of People's Liberation Army, Wuxi 214000, China.
  • Department of Neurologic Surgery, Mayo Clinic Florida, Jacksonville, FL 32224, USA.

Zitieren

APA

Lin, W., & Grewal, S. S. (2026). Deep Learning for Freezing of Gait Detection: Cross-Dataset Validation Reveals Critical Deployment Gaps Between Laboratory and Daily Living Wearable Monitoring. Sensors. https://doi.org/10.3390/s26041352

Vancouver

Lin W, Grewal SS. Deep Learning for Freezing of Gait Detection: Cross-Dataset Validation Reveals Critical Deployment Gaps Between Laboratory and Daily Living Wearable Monitoring. Sensors. 2026. doi:10.3390/s26041352

BibTeX
@article{Lin2026,
  author = {Lin, Wei and Grewal, Sanjeet S},
  title = {Deep Learning for Freezing of Gait Detection: Cross-Dataset Validation Reveals Critical Deployment Gaps Between Laboratory and Daily Living Wearable Monitoring},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26041352}
}
Kostenlos starten →