Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Zaid Farooq Pitafi und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical & Computer Engineering, University of Georgia, Athens, GA 30602, USA. Hauptthemen laut MEDLINE: Vital Signs. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Contactless monitoring of vital signs such as heart rate (HR) and respiratory rate (RR) has gained significant attention, with vibration-based sensors like geophones showing promise for accurate, non-invasive monitoring. However, most existing systems are developed with healthy subjects and may not generalize well to extreme physiological ranges, such as those observed in infants or patients with arrhythmia. Moreover, the underlying mechanisms of cardiorespiratory vibration dynamics remain insufficiently understood, limiting clinical adoption of these systems. To address these challenges, we present a programmable cardiorespiratory testbed capable of generating realistic HR and RR signals across a wide range (HR: 40–240 bpm, RR: 8–40 bpm). Our system uses a voice coil motor that acts as the vibration source, driven by a Raspberry Pi-based control circuit. Unlike similar systems that use separate modules for heart and lung signals, our setup generates both signals using a single motor. The synthetic signals exhibit a strong correlation of 0.85 compared with data from 75 human subjects. We use this system to design signal processing-based algorithms for vital signs monitoring and demonstrate their robustness for extreme physiological ranges. The proposed system enhances the understanding of cardiorespiratory vibration dynamics while significantly reducing the time and effort required to collect real-world data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vital SignsHumansMonitoring, PhysiologicHeart RateAlgorithmsSignal Processing, Computer-AssistedRespiratory RateVibration

Stichwörter der Autor:innen

algorithm validationcardiorespiratory testbedcontactless vital signs monitoringsignal processingsystem development

Autor:innen und Institutionen

  • School of Electrical & Computer Engineering, University of Georgia, Athens, GA 30602, USA.
  • School of Engineering and Materials Science, Queen Mary University of London, 327 Mile End Rd, Bethnal Green, London E1 4NS, UK.

ORCID-Profile: Zaid Farooq Pitafi

Zitieren

APA

Pitafi, Z. F., Yang, H., Chen, J., Song, Y., Ye, J., Tse, Z., Song, K., & Song, W. (2026). A Testbed for the Development and Validation of Contactless Vital Signs Monitoring Systems. Sensors. https://doi.org/10.3390/s26041092

Vancouver

Pitafi ZF, Yang H, Chen J, Song Y, Ye J, Tse Z, et al. A Testbed for the Development and Validation of Contactless Vital Signs Monitoring Systems. Sensors. 2026. doi:10.3390/s26041092

BibTeX
@article{Pitafi2026,
  author = {Pitafi, Zaid Farooq and Yang, He and Chen, Jiayu and Song, Yingjian and Ye, Jin and Tse, Zion and Song, Kenan and Song, WenZhan},
  title = {A Testbed for the Development and Validation of Contactless Vital Signs Monitoring Systems},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26041092}
}
Kostenlos starten →