Impact of Ethylene Oxide Sterilization on PEDOT:PSS Electrophysiology Electrodes
Sensors · 29.01.2026 · 26 (3) · 877
DOI: 10.3390/s26030877 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 29.01.2026. Verfasst von Ali Maziz und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laboratoire d'Analyse et d'Architecture des Systemes-Centre National de la Recherche Scientifique (LAAS-CNRS), 7 Avenue du Colonel Roche, 31400 Toulo…. Hauptthemen laut MEDLINE: Polystyrenes, Ethylene Oxide, Sterilization, Bridged Bicyclo Compounds, Heterocyclic. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Agence Nationale de la Recherche.
Abstract (Originalsprache)
Poly(3,4-ethylenedioxythiophene)–polystyrene sulfonate (PEDOT:PSS) is widely used to fabricate conductive organic coatings for electrodes in electrophysiology. As these devices move toward clinical translation, establishing sterilization methods that preserve their functional properties is essential. Ethylene oxide (EtO) is routinely used for sterilizing heat- and moisture-sensitive medical devices due to its high penetration efficiency and low thermal load. However, the absence of systematic studies evaluating its impact on PEDOT:PSS raises concerns about the compatibility of EtO sterilization with organic electrophysiology interfaces. Here, we report the first comprehensive evaluation of EtO sterilization on PEDOT:PSS electrodes electrochemically deposited onto cortical interfaces designed for intraoperative monitoring and stimulation. EtO exposure induced only minimal changes in surface topography, with no detectable alteration of the electrical or electrochemical performance of the electrodes. Impedance spectroscopy, cyclic voltammetry, and charge-injection capacity measurements all revealed that EtO-treated electrodes retained properties comparable to untreated controls. Moreover, EtO-sterilized PEDOT:PSS coatings demonstrated robust long-term stability under accelerated lifetime testing, exhibiting negligible degradation over extended operation. These findings demonstrate that EtO sterilization is fully compatible with PEDOT:PSS-based bioelectronic interfaces and constitutes a viable pathway toward their safe and effective integration into clinical electrophysiology. This work represents an important step toward translating organic conducting polymer technologies into real-world biomedical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratoire d'Analyse et d'Architecture des Systemes-Centre National de la Recherche Scientifique (LAAS-CNRS), 7 Avenue du Colonel Roche, 31400 Toulouse, France.
ORCID-Profile: Ali Maziz
Förderung
- Agence Nationale de la Recherche
Zitieren
APA
Maziz, A., Cointe, C., Reig, B., & Bergaud, C. (2026). Impact of Ethylene Oxide Sterilization on PEDOT:PSS Electrophysiology Electrodes. Sensors, 26(3), 877. https://doi.org/10.3390/s26030877
Vancouver
Maziz A, Cointe C, Reig B, Bergaud C. Impact of Ethylene Oxide Sterilization on PEDOT:PSS Electrophysiology Electrodes. Sensors. 2026;26(3):877. doi:10.3390/s26030877
BibTeX
@article{Maziz2026,
author = {Maziz, Ali and Cointe, Clement and Reig, Benjamin and Bergaud, Christian},
title = {Impact of Ethylene Oxide Sterilization on PEDOT:PSS Electrophysiology Electrodes},
journal = {Sensors},
year = {2026},
volume = {26},
number = {3},
pages = {877},
doi = {10.3390/s26030877}
}
EUVIMED