EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validation of Inertial Sensor-Based Step Detection Algorithms for Edge Device Deployment

Maksymilian Kisiel, Arslan Amjad, Agnieszka Szczęsna iD

Sensors · 29.01.2026 · 26 (3) · 876

DOI: 10.3390/s26030876 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 29.01.2026. Verfasst von Maksymilian Kisiel und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Graphics, Vision and Digital Systems, Faculty of Automatic Control, Electronics and Computer Science, Silesian University of T…. Hauptthemen laut MEDLINE: Algorithms, Walking, Monitoring, Ambulatory. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Step detection based on measurements of inertial measurement units (IMUs) is fundamental for human activity recognition, indoor navigation, and health monitoring applications. This study validates and compares five fundamentally different step detection algorithms for potential implementation on edge devices. A dedicated measurement system based on the Raspberry Pi Pico 2W microcontroller with two IMU sensors (Waveshare Pico-10DOF-IMU and Adafruit ST-9-DOF-Combo) was designed. The implemented algorithms include Peak Detection, Zero-Crossing, Spectral Analysis, Adaptive Threshold, and SHOE (Step Heading Offset Estimator). Validation was performed across 84 measurement sessions covering seven test scenarios (Timed Up and Go test, natural and fast walking, jogging, and stair climbing) and four sensor mounting locations (thigh pocket, ankle, wrist, and upper arm). Results demonstrate that Peak Detection achieved the best overall performance, with an average F1-score of 0.82, while Spectral Analysis excelled in stair scenarios (F1 = 0.86–0.92). Surprisingly, upper arm mounting yielded the highest accuracy (F1 = 0.84), outperforming ankle placement. The TUG clinical test proved most challenging (average F1 = 0.68), while fast walking was easiest (F1 = 0.87). Additionally, a preliminary application to 668 clinical TUG recordings from the open-access FRAILPOL database revealed algorithm-specific failure modes when continuous gait assumptions are violated. These findings provide practical guidelines for algorithm selection in edge computing applications and activity monitoring systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsWalkingMonitoring, AmbulatoryHumansGaitAccelerometry

Stichwörter der Autor:innen

edge computinggait analysisinertial measurement unit (IMU)signal processingstep detectionwearable sensors

Autor:innen und Institutionen

  • Department of Computer Graphics, Vision and Digital Systems, Faculty of Automatic Control, Electronics and Computer Science, Silesian University of Technology, 44-100 Gliwice, Poland.

ORCID-Profile: Agnieszka Szczęsna

Zitieren

APA

Kisiel, M., Amjad, A., & Szczęsna, A. (2026). Validation of Inertial Sensor-Based Step Detection Algorithms for Edge Device Deployment. Sensors, 26(3), 876. https://doi.org/10.3390/s26030876

Vancouver

Kisiel M, Amjad A, Szczęsna A. Validation of Inertial Sensor-Based Step Detection Algorithms for Edge Device Deployment. Sensors. 2026;26(3):876. doi:10.3390/s26030876

BibTeX
@article{Kisiel2026,
  author = {Kisiel, Maksymilian and Amjad, Arslan and Szczęsna, Agnieszka},
  title = {Validation of Inertial Sensor-Based Step Detection Algorithms for Edge Device Deployment},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {3},
  pages = {876},
  doi = {10.3390/s26030876}
}
Kostenlos starten →