Wearable ECG-PPG Deep Learning Model for Cardiac Index-Based Noninvasive Cardiac Output Estimation in Cardiac Surgery Patients
Sensors · 22.01.2026 · 26 (2) · 735
DOI: 10.3390/s26020735 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 22.01.2026. Verfasst von Minwoo Kim und 7 weiteren Autor:innen. Beteiligte Einrichtung: MEZOO Co., Ltd., 200, Gieopdosi-ro, Jijeong-myeon, Wonju-si 26354, Republic of Korea. Hauptthemen laut MEDLINE: Photoplethysmography, Wearable Electronic Devices, Deep Learning, Electrocardiography. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Ministry of Health and Welfare, Republic of Korea, the Ministry of SMEs and Startups, Republic of Korea, Ministry of Health and Welfare, Republic of Korea.
Abstract (Originalsprache)
Accurate cardiac output (CO) measurement is vital for hemodynamic management; however, it usually requires invasive monitoring, which limits its continuous and out-of-hospital use. Wearable sensors integrated with deep learning offer a noninvasive alternative. This study developed and validated a lightweight deep learning model using wearable electrocardiography (ECG) and photoplethysmography (PPG) signals to predict CO and examined whether cardiac index-based normalization (Cardiac Index (CI) = CO/body surface area) improves performance. Twenty-seven patients who underwent cardiac surgery and had pulmonary artery catheters were prospectively enrolled. Single-lead ECG (HiCardi+ chest patch) and finger PPG (WristOx2 3150) were recorded simultaneously and processed through an ECG–PPG fusion network with cross-modal interaction. Three models were trained as follows: (1) CI prediction, (2) direct CO prediction, and (3) indirect CO prediction. The total number of CO = predicted CI × body surface area. Reference values were derived from thermodilution. The CI model achieved the best performance, and the indirect CO model showed significant reductions in error/agreement metrics (MAE/RMSE/bias; p < 0.0001), while correlation-based metrics are reported descriptively without implying statistical significance. The Pearson correlation coefficient (PCC) and percentage error (PE) for the indirect CO estimates (PCC = 0.904; PE = 23.75%). The indirect CO estimates met the predefined PE < 30% agreement benchmark for method-comparison; this is not a universal clinical standard. These results demonstrate that wearable ECG–PPG fusion deep learning can achieve accurate, noninvasive CO estimation and that CI-based normalization enhances model agreement with pulmonary artery catheter measurements, supporting continuous catheter-free hemodynamic monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- MEZOO Co., Ltd., 200, Gieopdosi-ro, Jijeong-myeon, Wonju-si 26354, Republic of Korea.
- Division of Pulmonology and Critical Care Medicine, Department of Internal Medicine, Institute for Innovation in Digital Healthcare, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.
- Anaesthesia and Pain Research Institute, Department of Anaesthesiology and Pain Medicine, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.
- Division of Cardiovascular Surgery, Department of Cardiovascular and Thoracic Surgery, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.
- Institute for Innovation in Digital Healthcare, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.
ORCID-Profile: Minwoo Kim, Min Dong Sung, Sung Pil Cho, Junghwan Park, Sarah Soh, Hyun Chel Joo, Kyung Soo Chung
Förderung
- the Ministry of Health and Welfare, Republic of Korea
- the Ministry of SMEs and Startups, Republic of Korea
- Ministry of Health and Welfare, Republic of Korea
- Ministry of SMEs and Startups
Zitieren
APA
Kim, M., Sung, M. D., Jung, J., Cho, S. P., Park, J., Soh, S., Joo, H. C., & Chung, K. S. (2026). Wearable ECG-PPG Deep Learning Model for Cardiac Index-Based Noninvasive Cardiac Output Estimation in Cardiac Surgery Patients. Sensors, 26(2), 735. https://doi.org/10.3390/s26020735
Vancouver
Kim M, Sung MD, Jung J, Cho SP, Park J, Soh S, et al. Wearable ECG-PPG Deep Learning Model for Cardiac Index-Based Noninvasive Cardiac Output Estimation in Cardiac Surgery Patients. Sensors. 2026;26(2):735. doi:10.3390/s26020735
BibTeX
@article{Kim2026,
author = {Kim, Minwoo and Sung, Min Dong and Jung, Jimyeoung and Cho, Sung Pil and Park, Junghwan and Soh, Sarah and Joo, Hyun Chel and Chung, Kyung Soo},
title = {Wearable ECG-PPG Deep Learning Model for Cardiac Index-Based Noninvasive Cardiac Output Estimation in Cardiac Surgery Patients},
journal = {Sensors},
year = {2026},
volume = {26},
number = {2},
pages = {735},
doi = {10.3390/s26020735}
}
EUVIMED