Portable Raspberry Pi Platform for Automated Interpretation of Lateral Flow Strip Tests
Sensors · 2026
DOI: 10.3390/s26020598 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Natalia Nakou und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Patras, GR26504 Patras, Greece. Hauptthemen laut MEDLINE: SARS-CoV-2, COVID-19, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Paper-based rapid tests are widely used in point-of-care diagnostics due to their simplicity and low cost. However, their application in quantitative analysis remains limited. In this work, a nucleic acid lateral flow assay (NALFA) was integrated with an automated image acquisition system built on a Raspberry Pi platform for the quantitative detection of SARS-CoV-2 virus, increasing the accuracy of the test compared to subjective visual interpretation. The assay employed blue polystyrene microspheres as reporters, while automated image capturing, image processing and quantification were performed using custom Python software (version 3.12). Signal quantification was achieved by comparing the grayscale intensity of the test line with that of a simultaneously captured negative control strip, allowing correction for illumination and background variability. Calibration curves were used for the training of the algorithm. The system was applied for the analysis of a series of samples with varying DNA concentrations, yielding recoveries between 84 and 108%. The proposed approach integrates a simple biosensor with an accessible computational platform to achieve full low-cost automation. This work introduces the first Raspberry Pi-driven image processing approach for accurate quantification of NALFAs and establishes a foundation for future low-cost, portable diagnostic systems targeting diverse nucleic acids, proteins, and biomarkers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, University of Patras, GR26504 Patras, Greece.
ORCID-Profile: Panagiotis K Tsikas, Despina P Kalogianni
Zitieren
APA
Nakou, N., Tsikas, P. K., & Kalogianni, D. P. (2026). Portable Raspberry Pi Platform for Automated Interpretation of Lateral Flow Strip Tests. Sensors. https://doi.org/10.3390/s26020598
Vancouver
Nakou N, Tsikas PK, Kalogianni DP. Portable Raspberry Pi Platform for Automated Interpretation of Lateral Flow Strip Tests. Sensors. 2026. doi:10.3390/s26020598
BibTeX
@article{Nakou2026,
author = {Nakou, Natalia and Tsikas, Panagiotis K and Kalogianni, Despina P},
title = {Portable Raspberry Pi Platform for Automated Interpretation of Lateral Flow Strip Tests},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26020598}
}
EUVIMED