EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Interpretable Biomechanical Feature Selection for VR Exercise Assessment Using SHAP and LDA

Urszula Czajkowska iD, Magdalena Żuk, Michał Popek, Celina Pezowicz iD

Sensors · 2026

DOI: 10.3390/s26020464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Urszula Czajkowska und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspianskiego 27, 50-370 Wrocław, Poland. Hauptthemen laut MEDLINE: Virtual Reality, Exercise. Die Arbeit nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Centre for Research and Development in Poland, National Centre for Research and Development in Poland, institutional funds of Wroclaw University of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Virtual reality (VR) technologies are increasingly applied in rehabilitation, offering interactive physical and spatial exercises. A major challenge remains the objective assessment of human movement quality (HMQA). This study aimed to identify biomechanical features differentiating correct and incorrect execution of a lateral lunge and to determine the minimal number of sensors required for reliable VR-based motion analysis, prioritising interpretability. Thirty-two healthy adults (mean age: 26.4 ± 8.5 years) performed 211 repetitions recorded with the HTC Vive Tracker system (7 sensors + headset). Repetitions were classified by a physiotherapist using video observation and predefined criteria. The analysis included joint angles, angular velocities and accelerations, and Euclidean distances between 28 sensor pairs, evaluated with Linear Discriminant Analysis (LDA) and SHapley Additive exPlanations (SHAP). Angular features achieved higher LDA performance (F1 = 0.89) than distance-based features (F1 = 0.78), which proved more stable and less sensitive to calibration errors. Comparison of SHAP and LDA showed high agreement in identifying key features, including hip flexion, knee rotation acceleration, and spatial relations between headset and foot or shank sensors. The findings indicate that simplified sensor configurations may provide reliable diagnostic information, highlighting opportunities for interpretable VR-based rehabilitation systems in home and clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Virtual RealityExerciseHumansBiomechanical PhenomenaDiscriminant AnalysisAdultFemaleMaleMovementYoung Adult

Stichwörter der Autor:innen

SHapley additive explanations (SHAP)biomechanicshuman movement quality assessment (HMQA)linear discriminant analysis (LDA)motion analysisvirtual reality (VR)

Autor:innen und Institutionen

  • Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspianskiego 27, 50-370 Wrocław, Poland.

ORCID-Profile: Urszula Czajkowska, Celina Pezowicz

Förderung

  • the National Centre for Research and Development in Poland
  • National Centre for Research and Development in Poland
  • institutional funds of Wroclaw University of Science and Technology

Zitieren

APA

Czajkowska, U., Żuk, M., Popek, M., & Pezowicz, C. (2026). Interpretable Biomechanical Feature Selection for VR Exercise Assessment Using SHAP and LDA. Sensors. https://doi.org/10.3390/s26020464

Vancouver

Czajkowska U, Żuk M, Popek M, Pezowicz C. Interpretable Biomechanical Feature Selection for VR Exercise Assessment Using SHAP and LDA. Sensors. 2026. doi:10.3390/s26020464

BibTeX
@article{Czajkowska2026,
  author = {Czajkowska, Urszula and Żuk, Magdalena and Popek, Michał and Pezowicz, Celina},
  title = {Interpretable Biomechanical Feature Selection for VR Exercise Assessment Using SHAP and LDA},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26020464}
}
Kostenlos starten →