EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Feasibility Study of Using an In-Ear EEG System for a Quantitative Assessment of Stress and Mental Workload

Zhibo Fu iD, Kam Pang So iD, Xiaoli Wu iD, Arthit Khotsaenlee iD, Savio W H Wong iD, Chung Tin iD, Rosa H M Chan iD

Sensors · 2026

DOI: 10.3390/s26020442 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Zhibo Fu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, City University of Hong Kong, Hong Kong. Hauptthemen laut MEDLINE: Electroencephalography, Workload, Stress, Psychological. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hong Kong Innovation and Technology Commission, Research Grant Council Hong Kong.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

While electroencephalography (EEG) is effective for assessing stress and mental workload, its widespread adoption is currently hindered by the complex setup of most existing EEG systems. This article presents a new in-ear EEG system and investigates its feasibility for developing robust models to quantify stress and mental workload levels. The system consists of a single-channel EEG acquisition device that has a similar form factor as user-generic earpieces. All electrodes including passive, reference and bias electrodes were put on the ear, which optimized the device’s usability. We validated the system through two experiments with 66 subjects to collect EEG data under varying stress and mental workload conditions. We developed classification and regression models to predict stress and mental workload levels from the data. Cross-subject stress classification achieved 77% accuracy, while within-subject stress regression yielded an average R2 of 0.76 ± 0.20. Two-class mental workload level classification reached accuracies between 70% and 80% for the arithmetic and finger tapping tasks. Feature importance analysis revealed that frequency-domain EEG features, particularly in the alpha and beta bands, significantly contributed to the models’ performance. However, we observed lower within-subject feature variation and model accuracy for the mental rotation, potentially due to the distance between brain regions engaged and the device’s recording site. Our findings demonstrate the potential of using the presented EEG device to monitor stress and mental workload in real-time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyWorkloadStress, PsychologicalHumansFeasibility StudiesFemaleMaleAdultBrainElectrodesYoung Adult

Stichwörter der Autor:innen

EEGphysiological monitoringwearable sensors

Autor:innen und Institutionen

  • Department of Biomedical Engineering, City University of Hong Kong, Hong Kong.
  • MindAmp Limited, Hong Kong.
  • Department of Educational Psychology, The Chinese University of Hong Kong, Hong Kong.
  • Department of Electrical Engineering, City University of Hong Kong, Hong Kong.

ORCID-Profile: Zhibo Fu, Kam Pang So, Xiaoli Wu, Arthit Khotsaenlee, Savio W H Wong, Chung Tin, Rosa H M Chan

Förderung

  • Hong Kong Innovation and Technology Commission
  • Research Grant Council Hong Kong

Zitieren

APA

Fu, Z., So, K. P., Wu, X., Khotsaenlee, A., Wong, S. W. H., Tin, C., & Chan, R. H. M. (2026). A Feasibility Study of Using an In-Ear EEG System for a Quantitative Assessment of Stress and Mental Workload. Sensors. https://doi.org/10.3390/s26020442

Vancouver

Fu Z, So KP, Wu X, Khotsaenlee A, Wong SWH, Tin C, et al. A Feasibility Study of Using an In-Ear EEG System for a Quantitative Assessment of Stress and Mental Workload. Sensors. 2026. doi:10.3390/s26020442

BibTeX
@article{Fu2026,
  author = {Fu, Zhibo and So, Kam Pang and Wu, Xiaoli and Khotsaenlee, Arthit and Wong, Savio W H and Tin, Chung and Chan, Rosa H M},
  title = {A Feasibility Study of Using an In-Ear EEG System for a Quantitative Assessment of Stress and Mental Workload},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26020442}
}
Kostenlos starten →