EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dual-Stream STGCN with Motion-Aware Grouping for Rehabilitation Action Quality Assessment

Zhejun Kuang iD, Zhaotin Yin iD, Yuheng Yang iD, Jian Zhao iD, Lei Sun

Sensors · 02.01.2026 · 26 (1) · 287

DOI: 10.3390/s26010287 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 02.01.2026. Verfasst von Zhejun Kuang und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Computer Science and Technology, Changchun University, Changchun 130022, China. Hauptthemen laut MEDLINE: Rehabilitation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Development Plan of Jilin Province of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Action quality assessment automates the evaluation of human movement proficiency, which is vital for applications like sports training and rehabilitation, where objective feedback enhances patient outcomes. Action quality assessment processes motion capture data to generate quality scores for action execution. In rehabilitation exercises, joints typically work synergistically in functional groups. However, existing methods struggle to accurately model the collaborative relationships between joints. Fixed joint grouping is not flexible enough, while fully adaptive grouping lacks the guidance of prior knowledge. In this paper, based on rehabilitation theory in clinical medicine, we propose a dynamic, motion-aware grouping strategy. A two-stream architecture independently processes joint position and orientation information. Fused features are adaptively clustered into 6 functional groups by a joint motion energy-driven learnable mask generator, and intra-group temporal modeling and inter-group spatial projection are achieved through two-stage attention interaction. Our method achieves competitive results and obtains the best scores on most exercises of KIMORE, while remaining comparable on UI-PRMD. Experimental results using the KIMORE dataset show that the model outperforms current methods by reducing the mean absolute deviation by 26.5%. Ablation studies validate the necessity of dynamic grouping and the two-stream design. The core design principles of this study can be extended to fine-grained action-understanding tasks such as surgical operation assessment and motor skill quantification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RehabilitationHumansMotion CaptureAlgorithmsMovementMotion

Stichwörter der Autor:innen

action quality assessmentartificial neural networkphysical rehabilitation

Autor:innen und Institutionen

  • College of Computer Science and Technology, Changchun University, Changchun 130022, China.
  • Jilin Provincial Key Laboratory of Human Health Status Identification Function & Enhancement, Changchun 130022, China.
  • Key Laboratory of Intelligent Rehabilitation and Barrier-Free for the Disabled, Changchun University, Ministry of Education, Changchun 130022, China.
  • College of Computer Science and Technology, Jilin University, Changchun 130012, China.

ORCID-Profile: Zhejun Kuang, Zhaotin Yin, Yuheng Yang, Jian Zhao

Förderung

  • Science and Technology Development Plan of Jilin Province of China

Zitieren

APA

Kuang, Z., Yin, Z., Yang, Y., Zhao, J., & Sun, L. (2026). Dual-Stream STGCN with Motion-Aware Grouping for Rehabilitation Action Quality Assessment. Sensors, 26(1), 287. https://doi.org/10.3390/s26010287

Vancouver

Kuang Z, Yin Z, Yang Y, Zhao J, Sun L. Dual-Stream STGCN with Motion-Aware Grouping for Rehabilitation Action Quality Assessment. Sensors. 2026;26(1):287. doi:10.3390/s26010287

BibTeX
@article{Kuang2026,
  author = {Kuang, Zhejun and Yin, Zhaotin and Yang, Yuheng and Zhao, Jian and Sun, Lei},
  title = {Dual-Stream STGCN with Motion-Aware Grouping for Rehabilitation Action Quality Assessment},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {1},
  pages = {287},
  doi = {10.3390/s26010287}
}
Kostenlos starten →