EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of Benchtop and Portable Near-Infrared Instruments to Predict the Type of Microplastic Added to High-Moisture Food Samples

Adam Kolobaric iD, Shanmugam Alagappan, Jana Čaloudová iD, Louwrens C Hoffman iD, James Chapman, Daniel Cozzolino iD

Sensors · 2025

DOI: 10.3390/s26010210 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Sensors, 2025. Verfasst von Adam Kolobaric und 5 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Nutrition and Food Sciences (CNAFS), Queensland Alliance for Agriculture and Food Innovation (QAAFI), The University of Queensland, St. Lu…. Hauptthemen laut MEDLINE: Microplastics, Food Analysis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Near-infrared (NIR) spectroscopy is a rapid, non-destructive analytical tool widely used in the food and agricultural sectors. In this study, two NIR instruments were compared for classifying the addition of microplastics (MPs) to high-moisture-content samples such as vegetables and fruit. Polyethylene (PE), polypropylene (PP), and a mix of polymers (PE + PP) MP were added to mixtures of spinach and banana and scanned using benchtop (Bruker Tango) and portable (MicroNIR) instruments. Both principal component analysis (PCA) and partial least squares (PLS) were used to analyze and interpret the spectra of the samples. Quantitative models were developed to predict the addition of Mix, PP, or PE to spinach and banana samples using PLS regression. The R2 CV and the SECV obtained were 0.88 and 0.44 for the benchtop samples, and 0.54 and 0.67 for the portable instruments, respectively. Two wavenumber regions were also evaluated: 11,520–7500 cm−1 (short to medium wavelengths), and 7500–4200 cm−1 (long wavelengths). The R2 CV and the SECV obtained were 0.88 and 0.46, 0.86 and 0.49, respectively, for the prediction of addition in samples analyzed on the benchtop instrument using short and long wavenumbers, respectively. This study provides new insights into the comparison of two instruments for detecting the addition of MPs in high-moisture samples. The results of this study will ensure that NIR can be utilized not only to measure the quality of these samples but also to monitor MPs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroplasticsFood AnalysisSpectroscopy, Near-InfraredPrincipal Component AnalysisMusaLeast-Squares AnalysisSpinacia oleraceaPolypropylenesFruitPolyethylene

Stichwörter der Autor:innen

bananaclassificationmicroplasticsnear-infraredspinach

Substanzen

MicroplasticsPolypropylenesPolyethylene

Autor:innen und Institutionen

  • Centre for Nutrition and Food Sciences (CNAFS), Queensland Alliance for Agriculture and Food Innovation (QAAFI), The University of Queensland, St. Lucia Campus, Brisbane, QLD 4067, Australia.
  • Department of Plant Origin Food Sciences, Faculty of Veterinary Hygiene and Ecology, University of Veterinary Sciences Brno, 612 42 Brno, Czech Republic.
  • School of the Environment and Science-Chemistry and Forensic Science, Griffith University, Gold Coast, QLD 4215, Australia.

ORCID-Profile: Adam Kolobaric, Jana Čaloudová, Louwrens C Hoffman, Daniel Cozzolino

Zitieren

APA

Kolobaric, A., Alagappan, S., Čaloudová, J., Hoffman, L. C., Chapman, J., & Cozzolino, D. (2025). Comparison of Benchtop and Portable Near-Infrared Instruments to Predict the Type of Microplastic Added to High-Moisture Food Samples. Sensors. https://doi.org/10.3390/s26010210

Vancouver

Kolobaric A, Alagappan S, Čaloudová J, Hoffman LC, Chapman J, Cozzolino D. Comparison of Benchtop and Portable Near-Infrared Instruments to Predict the Type of Microplastic Added to High-Moisture Food Samples. Sensors. 2025. doi:10.3390/s26010210

BibTeX
@article{Kolobaric2025,
  author = {Kolobaric, Adam and Alagappan, Shanmugam and Čaloudová, Jana and Hoffman, Louwrens C and Chapman, James and Cozzolino, Daniel},
  title = {Comparison of Benchtop and Portable Near-Infrared Instruments to Predict the Type of Microplastic Added to High-Moisture Food Samples},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s26010210}
}
Kostenlos starten →