EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electromyography (EMG) Signal Processing to Evaluate Low-Frequency Tremors

Samantha O'Sullivan iD, Mark Daly iD, Niall Murray iD, Thiago Braga Rodrigues iD

Sensors · 25.12.2025 · 26 (1) · 157

DOI: 10.3390/s26010157 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 25.12.2025. Verfasst von Samantha O'Sullivan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering & Technology, The Technological University of the Shannon: Midlands Midwest, N37 HD68 Athlone, Ireland. Hauptthemen laut MEDLINE: Electromyography, Signal Processing, Computer-Assisted, Tremor. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective quantification of tremor remains a challenge in Parkinson’s disease (PD) assessment, with current clinical assessments relying largely on subjective scale ratings. This study evaluates the feasibility and signal behaviour of integrating surface electromyography (sEMG) with MDS-UPDRS-aligned tasks in a healthy adult cohort, with the aim of establishing normative low-frequency muscle activation profiles. Thirty-two healthy participants (mean age 27.6 ± 5.3 years) completed seven upper-limb tasks derived from the MDS-UPDRS while sEMG data were recorded from antagonistic forearm muscles. Signals were normalised using maximum voluntary contraction, filtered at 14 Hz, and analysed using frequency-domain (FFT) and time-frequency (STFT) methods. Significant task-dependent differences were observed in both frequency occurrence and magnitude (p < 0.05), particularly within the 3.5–9 Hz range. Finger tapping elicited increased low-frequency activity compared to baseline, while pronation–supination produced the most stable and consistent muscle activation across participants. Frequencies above 12 Hz showed minimal task discrimination. These findings demonstrate that low-frequency tremor-like activity can occur during specific MDS-UPDRS tasks in healthy individuals and may require further validation before being considered suitable for PD staging. This work establishes normative sEMG benchmarks to support future clinical validation and PD cohort comparisons.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectromyographySignal Processing, Computer-AssistedTremorHumansMaleFemaleAdultParkinson DiseaseMuscle, SkeletalYoung Adult

Stichwörter der Autor:innen

MDS-UPDRSelectromyographyhealthy subjectslow frequency signalsmovement disorderssignal processingtask basedtremors

Autor:innen und Institutionen

  • Department of Engineering & Technology, The Technological University of the Shannon: Midlands Midwest, N37 HD68 Athlone, Ireland.

ORCID-Profile: Samantha O'Sullivan, Mark Daly, Niall Murray, Thiago Braga Rodrigues

Zitieren

APA

O'Sullivan, S., Daly, M., Murray, N., & Rodrigues, T. B. (2025). Electromyography (EMG) Signal Processing to Evaluate Low-Frequency Tremors. Sensors, 26(1), 157. https://doi.org/10.3390/s26010157

Vancouver

O'Sullivan S, Daly M, Murray N, Rodrigues TB. Electromyography (EMG) Signal Processing to Evaluate Low-Frequency Tremors. Sensors. 2025;26(1):157. doi:10.3390/s26010157

BibTeX
@article{OSullivan2025,
  author = {O'Sullivan, Samantha and Daly, Mark and Murray, Niall and Rodrigues, Thiago Braga},
  title = {Electromyography (EMG) Signal Processing to Evaluate Low-Frequency Tremors},
  journal = {Sensors},
  year = {2025},
  volume = {26},
  number = {1},
  pages = {157},
  doi = {10.3390/s26010157}
}
Kostenlos starten →