EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

From Laboratory to Field: Concurrent Validity of Kinovea’s Linear Kinematics Tracking Tool for Semi-Automated Countermovement Jump Analysis

Lucija Faj iD, Jelena Aleksić iD, Olivera M Knežević iD, Branislav Božović iD, Hrvoje Brkić iD, Damir Sekulić iD, Dragan M Mirkov iD

Sensors · 19.12.2025 · 26 (1) · 24

DOI: 10.3390/s26010024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 19.12.2025. Verfasst von Lucija Faj und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Kinesiology, University of Osijek, 31000 Osijek, Croatia. Hauptthemen laut MEDLINE: Biomechanical Phenomena. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: FDMZ Osijek Research Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Affordable high-frame-rate cameras and open-source software, such as Kinovea (ver. 2025.1.0), have expanded the potential for conducting kinematic assessments outside laboratory settings. This study examined the reliability and validity of Kinovea’s semi-automated linear kinematics tracking tool by comparing its outputs with those from a 3D marker-based motion capture system (Qualisys). Ten recreationally active male basketball players (x̄ ± SD: age 23.7 ± 1.7 years; height 183 ± 5 cm; body mass 76.8 ± 9.8 kg) performed three CMJ trials, simultaneously recorded using both systems. Reflective markers placed on the shoulder, hip, and knee were tracked in Kinovea by two raters with different levels of experience to extract core CMJ variables (total take-off time and maximum vertical displacement) and complementary variables (eccentric and propulsion duration, and minimum vertical displacement). Inter-rater reliability and concurrent validity were evaluated using intraclass correlation coefficients (ICCs), coefficients of variation (CV%), standard error of measurement (SEM), and Bland–Altman analysis. Results showed excellent inter-rater reliability (ICC = 0.73–0.99) across all markers, with the hip and knee demonstrating the highest consistency. Strong validity relative to Qualisys was observed for both raters (ICC = 0.68–0.99; r > 0.80), with small systematic biases primarily in temporal variables. Collectively, these findings demonstrate that Kinovea’s semi-automated 2D analysis yields reliable and valid CMJ measurements comparable to 3D motion capture, even for less experienced users. As a free and easily deployable tool, it offers a widely accessible alternative for field-based performance monitoring and applied biomechanics research where laboratory-grade equipment is not available.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biomechanical PhenomenaAdultHumansMaleYoung AdultBasketballReproducibility of ResultsSoftware

Stichwörter der Autor:innen

markerless motion captureperformance monitoringsports biomechanicsvertical jump performancevideo analysis

Autor:innen und Institutionen

  • Faculty of Kinesiology, University of Osijek, 31000 Osijek, Croatia.
  • Faculty of Sport and Physical Education, University of Belgrade, Blagoja Parovica 156, 11000 Belgrade, Serbia.
  • Faculty of Medicine, University of Osijek, 31000 Osijek, Croatia.
  • Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia.
  • Faculty of Kinesiology, University of Split, 21000 Split, Croatia.

ORCID-Profile: Lucija Faj, Jelena Aleksić, Olivera M Knežević, Branislav Božović, Hrvoje Brkić, Damir Sekulić, Dragan M Mirkov

Förderung

  • FDMZ Osijek Research Fund

Zitieren

APA

Faj, L., Aleksić, J., Knežević, O. M., Božović, B., Brkić, H., Sekulić, D., & Mirkov, D. M. (2025). From Laboratory to Field: Concurrent Validity of Kinovea’s Linear Kinematics Tracking Tool for Semi-Automated Countermovement Jump Analysis. Sensors, 26(1), 24. https://doi.org/10.3390/s26010024

Vancouver

Faj L, Aleksić J, Knežević OM, Božović B, Brkić H, Sekulić D, et al. From Laboratory to Field: Concurrent Validity of Kinovea’s Linear Kinematics Tracking Tool for Semi-Automated Countermovement Jump Analysis. Sensors. 2025;26(1):24. doi:10.3390/s26010024

BibTeX
@article{Faj2025,
  author = {Faj, Lucija and Aleksić, Jelena and Knežević, Olivera M and Božović, Branislav and Brkić, Hrvoje and Sekulić, Damir and Mirkov, Dragan M},
  title = {From Laboratory to Field: Concurrent Validity of Kinovea’s Linear Kinematics Tracking Tool for Semi-Automated Countermovement Jump Analysis},
  journal = {Sensors},
  year = {2025},
  volume = {26},
  number = {1},
  pages = {24},
  doi = {10.3390/s26010024}
}
Kostenlos starten →