OH* 3D Concentration Measurement of Non-Axisymmetric Flame via Near-Ultraviolet Volumetric Emission Tomography
Sensors · 19.12.2025 · 26 (1) · 9
DOI: 10.3390/s26010009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 19.12.2025. Verfasst von Junhui Ma und 5 weiteren Autor:innen. Beteiligte Einrichtung: MIIT Key Laboratory of Complex-Field Intelligent Exploration, School of Optics and Photonics, Beijing Institute of Technology, 5 Zhongguancun South S…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ye Qisun Science Foundation of National Natural Science Foundation of China.
Abstract (Originalsprache)
Measuring the three-dimensional (3D) concentration of the ubiquitous intermediate OH* across combustion systems, spanning carbon-based fuels to zero-carbon alternatives such as H2 and NH3, provides vital insights into flame topology, reaction pathways, and emission formation mechanisms. Optical imaging methods have attracted vital interests due to non-intrusiveness in the combustion process. However, achieving accurate 3D concentration of OH* via imaging in non-axisymmetric flames remains challenging. This work presents a near-ultraviolet (NUV) volumetric emission tomography-based OH* measuring method that integrates a three-layer OH* imaging model, a calibration procedure utilizing narrow-band NUV radiometry, and a threshold-constrained Local Filtered Back-Projection Simultaneous Algebraic Reconstruction Technique (LFBP-SART) algorithm. When applied to a non-axisymmetric Bunsen flame, the method reveals multiple small flame structures matching the fairing pattern in the reconstructed 3D OH* field, with a maximum OH* molar concentration of approximately 0.04 mol/m3 and an overall relative uncertainty of about 8.7%. Given its straightforward requirements, this technique is considered adaptable to other free radicals.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- MIIT Key Laboratory of Complex-Field Intelligent Exploration, School of Optics and Photonics, Beijing Institute of Technology, 5 Zhongguancun South Street, Beijing 100081, China.
- Beijing Institute of Technology, Zhuhai Campus, 6 Jinfeng Road, Tangjiawan, Zhuhai 519088, China.
Förderung
- Ye Qisun Science Foundation of National Natural Science Foundation of China
Zitieren
APA
Ma, J., Wang, L., Chen, D., Zheng, D., Kang, G., & Cai, Y. (2025). OH* 3D Concentration Measurement of Non-Axisymmetric Flame via Near-Ultraviolet Volumetric Emission Tomography. Sensors, 26(1), 9. https://doi.org/10.3390/s26010009
Vancouver
Ma J, Wang L, Chen D, Zheng D, Kang G, Cai Y. OH* 3D Concentration Measurement of Non-Axisymmetric Flame via Near-Ultraviolet Volumetric Emission Tomography. Sensors. 2025;26(1):9. doi:10.3390/s26010009
BibTeX
@article{Ma2025,
author = {Ma, Junhui and Wang, Lingxue and Chen, Dongqi and Zheng, Dezhi and Kang, Guoguo and Cai, Yi},
title = {OH* 3D Concentration Measurement of Non-Axisymmetric Flame via Near-Ultraviolet Volumetric Emission Tomography},
journal = {Sensors},
year = {2025},
volume = {26},
number = {1},
pages = {9},
doi = {10.3390/s26010009}
}
EUVIMED