EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Implementation of Vital Signs Detection Algorithm for Supervising the Evacuation of Individuals with Special Needs

Krzysztof Konopko iD, Dariusz Janczak iD, Wojciech Walendziuk iD

Sensors · 2025

DOI: 10.3390/s25237391 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Krzysztof Konopko und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Electrical Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland. Hauptthemen laut MEDLINE: Algorithms, Vital Signs. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bialystok University of Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The article describes a system for monitoring the vital parameters of evacuated individuals, integrating three key functionalities: pulse detection, verification of wristband contact with the skin, and motion recognition. For pulse detection, the system employs the MAX30102 optical sensor and a signal processing algorithm presented in the study. The algorithm is based on spectral analysis using the Fast Fourier Transform (FFT) and incorporates a nonparametric estimator of the probability density function (PDF) in the form of Kernel Density Estimation (KDE). This developed real-time algorithm enables reliable assessment of vital parameters of evacuated individuals. The wristband contact with the skin is verified by measuring the brightness of backscattered light and the temperature of the wrist. Motion detection is achieved using the MPU-9250 inertial module, which analyzes acceleration across three axes. This allows the system to distinguish between states of rest and physical activity, which is crucial for accurately interpreting vital parameters during evacuation. The experimental studies, which were performed on a representative group of individuals, confirmed the correctness of the developed algorithm. The system ensures reliable monitoring of vital parameters by combining precise pulse detection, skin contact verification, and motion analysis. The classifier achieves nearly 95% accuracy and an F1-score of 0.9465, which indicates its high quality. This level of effectiveness can be considered fully satisfactory for evacuation monitoring systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsVital SignsHumansMonitoring, PhysiologicSignal Processing, Computer-AssistedDetection Algorithms

Stichwörter der Autor:innen

Fast Fourier TransformIMUPPG sensoraccelerometerevacuationheart rate measurementkernel density estimationmonitoring bandpulse detectionsmart bandvital sign detection

Autor:innen und Institutionen

  • Faculty of Electrical Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland.

ORCID-Profile: Krzysztof Konopko, Dariusz Janczak, Wojciech Walendziuk

Förderung

  • Bialystok University of Technology

Zitieren

APA

Konopko, K., Janczak, D., & Walendziuk, W. (2025). Implementation of Vital Signs Detection Algorithm for Supervising the Evacuation of Individuals with Special Needs. Sensors. https://doi.org/10.3390/s25237391

Vancouver

Konopko K, Janczak D, Walendziuk W. Implementation of Vital Signs Detection Algorithm for Supervising the Evacuation of Individuals with Special Needs. Sensors. 2025. doi:10.3390/s25237391

BibTeX
@article{Konopko2025,
  author = {Konopko, Krzysztof and Janczak, Dariusz and Walendziuk, Wojciech},
  title = {Implementation of Vital Signs Detection Algorithm for Supervising the Evacuation of Individuals with Special Needs},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25237391}
}