EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

From Static to Dynamic: Complementary Roles of FSR and Piezoelectric Sensors in Wearable Gait and Pressure Monitoring

Sara Sêco, Vítor Miguel Santos iD, Sara Valvez iD, Beatriz Branquinho Gomes iD, Maria Augusta Neto iD, Ana Martins Amaro iD

Sensors · 2025

DOI: 10.3390/s25237377 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Sara Sêco und 5 weiteren Autor:innen. Beteiligte Einrichtung: University of Coimbra, Department of Physics, 3040-516 Coimbra, Portugal. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Gait. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia (FCT).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Plantar pressure abnormalities have a significant impact on mobility and quality of life. Real-time pressure monitoring is essential in clinical and rehabilitation settings for assessing patient progress and refining treatment protocols. Instrumental and particularly smart insoles offer a promising solution by collecting biomechanical data during daily activities. However, determining the optimal combination of sensor type, number, and placement remains a key challenge for ensuring accurate and reliable measurements. This study proposes a methodology for identifying the most appropriate sensor technology for wearable insoles, with a focus on data accuracy, system efficiency, and practical applicability. Additionally, it examines the correlation between sensor signals and material behavior during compression testing.

Methods

Two insole prototypes underwent compression testing: one equipped with a Force Sensitive Resistor (FSR) sensor and one with a piezoelectric sensor, both positioned at the heel. Three trials per prototype assessed consistency and repeatability. Real-time data acquisition utilized a microcontroller system, and signals were processed using a sixth-order Butterworth low-pass filter with a 5 Hz cutoff frequency to reduce noise.

Results

FSR sensors demonstrated stable static responses but saturated rapidly beyond 20 N, with performance degradation observed after repeated loading cycles. Piezoelectric sensors exhibited excellent dynamic sensitivity with sharp voltage peaks but proved unable to measure sustained static pressure.

Conclusions

FSR sensors are well-suited for static postural assessment and continuous pressure monitoring, while piezoelectric sensors excel in dynamic gait analysis. This comparative framework establishes a foundation for developing future smart insole systems that deliver accurate, real-time rehabilitation monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesGaitHumansPressureMonitoring, PhysiologicBiosensing TechniquesBiomechanical PhenomenaFootEquipment Design

Stichwörter der Autor:innen

compression testinginstrumented insolespressure sensorsprototyperehabilitation

Autor:innen und Institutionen

  • University of Coimbra, Department of Physics, 3040-516 Coimbra, Portugal.
  • University of Coimbra, Centre of Mechanical Engineering, Materials and Processes (CEMMPRE-ARISE), Department of Mechanical Engineering, 3040-248 Coimbra, Portugal.
  • University of Coimbra, Interdisciplinary Center for the Study of Human Performance (CIPER), Faculty of Sports Sciences and Physical Education (FCDEF), 3040-256 Coimbra, Portugal.

ORCID-Profile: Vítor Miguel Santos, Sara Valvez, Beatriz Branquinho Gomes, Maria Augusta Neto, Ana Martins Amaro

Förderung

  • Fundação para a Ciência e Tecnologia (FCT)

Zitieren

APA

Sêco, S., Santos, V. M., Valvez, S., Gomes, B. B., Neto, M. A., & Amaro, A. M. (2025). From Static to Dynamic: Complementary Roles of FSR and Piezoelectric Sensors in Wearable Gait and Pressure Monitoring. Sensors. https://doi.org/10.3390/s25237377

Vancouver

Sêco S, Santos VM, Valvez S, Gomes BB, Neto MA, Amaro AM. From Static to Dynamic: Complementary Roles of FSR and Piezoelectric Sensors in Wearable Gait and Pressure Monitoring. Sensors. 2025. doi:10.3390/s25237377

BibTeX
@article{Sco2025,
  author = {Sêco, Sara and Santos, Vítor Miguel and Valvez, Sara and Gomes, Beatriz Branquinho and Neto, Maria Augusta and Amaro, Ana Martins},
  title = {From Static to Dynamic: Complementary Roles of FSR and Piezoelectric Sensors in Wearable Gait and Pressure Monitoring},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25237377}
}
Kostenlos starten →