EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Novel Wearable-Based Real-Time Temperature Monitoring in Hospitals for Febrile Adverse Events in Patients with Cancer: A Prospective Feasibility Study

Yun Kwan Kim iD, Seo-Yeon Ahn, Sun Jung Lee, Chae-Bin Song, YeWon Hong iD, Ray Kim, Hee Jo Baek, Hoon Kook, Mihee Kim iD, Ga-Young Song iD, Ho Cheol Jang, Sung-Hoon Jung und 7 weitere

Sensors · 2025

DOI: 10.3390/s25237111 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Yun Kwan Kim und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Research and Development, SEERS Technology Co., Ltd., Pyeongtaek 17707, Gyeonggi-do, Republic of Korea. Hauptthemen laut MEDLINE: Fever, Wearable Electronic Devices, Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Korea Health Industry Development Institute, the Institute for Biomedical Science, Chonnam National University Hwasun Hospital, Ministry of Health and Welfare, Republic of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cancer remains a leading cause of mortality worldwide. Chemotherapy is effective but can cause febrile neutropenia, deplete neutrophils, and increase infection risk. Although timely fever detection is critical to prevent complications, periodic temperature monitoring has inherent limitations. Wearable devices (WDs) for real-time body temperature (RBT) monitoring are emerging as tools for early fever detection, though their clinical feasibility and usability remain unverified. This study assessed the clinical feasibility of a novel WD by comparing its temperature concordance and fever detection capability against a standard reference in patients with cancer. The RBT system’s clinical maturity, including its capacity for early fever detection and monitoring treatment-related changes, was evaluated. Furthermore, satisfaction among clinicians and patients was analyzed in a hospital setting. In this prospective study, patients with hematologic malignancies at high infection risk admitted to the Chonnam National University in Hwasun Hospital, South Korea, were enrolled. Data from 47 patients were analyzed to compare MT100D as WD (SEERS Technology Co., Ltd., South Korea) readings with axillary thermometers. Temperature concordance was evaluated using the intraclass correlation coefficient (ICC), and diagnostic performance was compared with the reference thermometer. The early fever detection performance of the MT100D was analyzed to evaluate the clinical effectiveness of the early response system. Usability was evaluated through a five-point Likert scale survey completed by clinical nurses. The MT100D demonstrated good agreement with the reference thermometer (mean difference: −0.19 ± 0.35 °C; ICC: 0.78). The RBT system achieved sensitivity, specificity, and area under the receiver operating characteristic curve values of 81.50%, 96.32%, and 96.60%, respectively. The early fever detection rate was 77.1%, with the RBT system detecting fever an average of 1.13 ± 1.28 h earlier than the reference. Usability and satisfaction assessments showed high patient satisfaction (mean 4.69 ± 0.5; range 4.57–4.80) and moderate clinician satisfaction (mean 3.63 ± 0.75; range 2.89–4.11). Among patients with cancer, including those at risk of febrile neutropenia, the MT100D demonstrated strong concordance with standard thermometry, enabling early fever detection. The RBT system shows promise for the early identification of neutropenic risk during chemotherapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FeverWearable Electronic DevicesNeoplasmsHumansMaleFemaleFeasibility StudiesProspective StudiesMiddle AgedBody TemperatureMonitoring, PhysiologicAgedAdultHospitalsRepublic of Korea

Stichwörter der Autor:innen

cancerfebrile neutropeniareal-time temperature monitoringwearable device

Autor:innen und Institutionen

  • Department of Research and Development, SEERS Technology Co., Ltd., Pyeongtaek 17707, Gyeonggi-do, Republic of Korea.
  • Department of Hematology-Oncology, Chonnam National University Hwasun Hospital, Hwasun-gun 58128, Jeollanam-do, Republic of Korea.
  • Strategic Planning Team, SEERS Technology Co., Ltd., Pyeongtaek 17707, Gyeonggi-do, Republic of Korea.
  • Department of Pediatrics, Chonnam National University Hwasun Hospital, Hwasun-gun 58128, Jeollanam-do, Republic of Korea.

ORCID-Profile: Yun Kwan Kim, YeWon Hong, Mihee Kim, Ga-Young Song, Gyung Chul Kim, Young-Shin Lee

Förderung

  • the Korea Health Industry Development Institute
  • the Institute for Biomedical Science, Chonnam National University Hwasun Hospital
  • Ministry of Health and Welfare, Republic of Korea
  • Institute for Biomedical Science, Chonnam National University Hwasun Hospital

Zitieren

APA

Kim, Y. K., Ahn, S. Y., Lee, S. J., Song, C. B., Hong, Y., Kim, R., Baek, H. J., Kook, H., Kim, M., Song, G. Y., Jang, H. C., Jung, S. H., Yang, D. H., Lee, J. J., Kim, H. J., Kim, G. C., Kim, H. H., Lee, Y. S., & Ahn, J. S. (2025). Novel Wearable-Based Real-Time Temperature Monitoring in Hospitals for Febrile Adverse Events in Patients with Cancer: A Prospective Feasibility Study. Sensors. https://doi.org/10.3390/s25237111

Vancouver

Kim YK, Ahn SY, Lee SJ, Song CB, Hong Y, Kim R, et al. Novel Wearable-Based Real-Time Temperature Monitoring in Hospitals for Febrile Adverse Events in Patients with Cancer: A Prospective Feasibility Study. Sensors. 2025. doi:10.3390/s25237111

BibTeX
@article{Kim2025,
  author = {Kim, Yun Kwan and Ahn, Seo-Yeon and Lee, Sun Jung and Song, Chae-Bin and Hong, YeWon and Kim, Ray and Baek, Hee Jo and Kook, Hoon and Kim, Mihee and Song, Ga-Young and Jang, Ho Cheol and Jung, Sung-Hoon and Yang, Deok-Hwan and Lee, Je-Jung and Kim, Hyeoung-Joon and Kim, Gyung Chul and Kim, Hoo Hyun and Lee, Young-Shin and Ahn, Jae-Sook},
  title = {Novel Wearable-Based Real-Time Temperature Monitoring in Hospitals for Febrile Adverse Events in Patients with Cancer: A Prospective Feasibility Study},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25237111}
}
Kostenlos starten →