Broken Rotor Bar Fault Detection for Inverter-Fed Induction Motor with Negative-Sequence Current Analysis
Sensors · 18.11.2025 · 25 (22) · 7045
DOI: 10.3390/s25227045 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 18.11.2025. Verfasst von Sarvarbek Ruzimov und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering, Southeast University, Nanjing 210096, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation of China.
Abstract (Originalsprache)
This study examines the effectiveness of negative-sequence current analysis in identifying broken rotor bars for inverter-fed induction motors under different load and speed conditions. To improve diagnostic reliability, inverter-induced harmonics in the negative-sequence current were separated using a Spectrum-Tracking Hybrid Adaptive Extended Kalman Filter method, resulting in a clearer signal representation. A thorough assessment of the fault detection accuracy and sensitivity was performed to measure fault visibility and clarity. Visual comparisons of healthy and faulty negative-sequence current signals validated comparable patterns of anomalies. The findings validate that negative-sequence current analysis, enhanced by extended Kalman filter-based harmonic isolation, is a dependable and resilient technique for detecting broken rotor bars, especially in the early stages of faults and under various operating conditions.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electrical Engineering, Southeast University, Nanjing 210096, China.
ORCID-Profile: Sarvarbek Ruzimov, Jianzhong Zhang, Xu Huang, Muhammad Shahzad Aziz
Förderung
- National Science Foundation of China
Zitieren
APA
Ruzimov, S., Zhang, J., Huang, X., & Aziz, M. S. (2025). Broken Rotor Bar Fault Detection for Inverter-Fed Induction Motor with Negative-Sequence Current Analysis. Sensors, 25(22), 7045. https://doi.org/10.3390/s25227045
Vancouver
Ruzimov S, Zhang J, Huang X, Aziz MS. Broken Rotor Bar Fault Detection for Inverter-Fed Induction Motor with Negative-Sequence Current Analysis. Sensors. 2025;25(22):7045. doi:10.3390/s25227045
BibTeX
@article{Ruzimov2025,
author = {Ruzimov, Sarvarbek and Zhang, Jianzhong and Huang, Xu and Aziz, Muhammad Shahzad},
title = {Broken Rotor Bar Fault Detection for Inverter-Fed Induction Motor with Negative-Sequence Current Analysis},
journal = {Sensors},
year = {2025},
volume = {25},
number = {22},
pages = {7045},
doi = {10.3390/s25227045}
}
EUVIMED