Evaluation of Reaction Time and Hand–Eye Coordination in Schoolchildren Using Wearable Sensor-Based Systems: A Study with Neural Trainer Devices
Sensors · 2025
DOI: 10.3390/s25227006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von José Alfredo Sulla-Torres und 5 weiteren Autor:innen. Beteiligte Einrichtung: Escuela Profesional de Ingeniería de Sistemas, Universidad Católica de Santa María, Arequipa 04001, Peru. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Reaction Time, Hand, Psychomotor Performance. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Catholic University of Santa María, Universidad Católica de Santa María.
Abstract (Originalsprache)
Reaction time and hand–eye coordination are critical neuromotor skills in school-aged children, influencing academic, cognitive, and motor development. The objective of this study was to evaluate schoolchildren’s performance on reaction time tests using Neural Trainer device sensors and wearable technology, establishing baseline metrics and identifying lateral performance asymmetries. Fifty-nine schoolchildren performed six sensor-based motor tests involving bimanual and unimanual interaction: P1 (10 timed repetitions, bimanual), P2 (10 timed repetitions, left hand), P3 (10 timed repetitions, right hand), P4 (hits, bimanual), P5 (hits, left hand), and P6 (hits, right hand). Neural Trainer devices with four light nodes were used for activity monitoring. Data was analyzed using statistical methods to assess time, accuracy, and variability. The results showed that the average times were P1 = 8.69 ± 1.44 s, P2 = 8.90 ± 1.30 s, and P3 = 8.83 ± 1.29 s. The average successes were P4 = 22.90 ± 3.10, P5 = 22.00 ± 3.40, and P6 = 24.42 ± 2.72 hits. Significant differences were found between hands in successes (p < 0.001) but not in times (p = 0.716). The ANOVA for the hit trials revealed significant differences between conditions, F(2, 174) = 9.30, p < 0.001. The conclusions indicate that sensor-based systems such as the Neural Trainer device demonstrated the potential to provide objective and consistent measurements of reaction time in schoolchildren; however, further studies comparing its performance with established clinical assessment tools are necessary to confirm its validity and diagnostic accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Escuela Profesional de Ingeniería de Sistemas, Universidad Católica de Santa María, Arequipa 04001, Peru.
- Programa de Doctorado en Ciencias de la Actividad Física, Universidad Católica del Maule, Talca 3466706, Chile.
ORCID-Profile: José Alfredo Sulla-Torres, Nadia Yunorvi Chavez-Salas, María Fernanda Valverde-Riveros, Diego Alonso Iquira-Becerra, Karina Rosas-Paredes, Marco Antonio Cossio-Bolaños
Förderung
- Catholic University of Santa María
- Universidad Católica de Santa María
Zitieren
APA
Sulla-Torres, J. A., Chavez-Salas, N. Y., Valverde-Riveros, M. F., Iquira-Becerra, D. A., Rosas-Paredes, K., & Cossio-Bolaños, M. A. (2025). Evaluation of Reaction Time and Hand–Eye Coordination in Schoolchildren Using Wearable Sensor-Based Systems: A Study with Neural Trainer Devices. Sensors. https://doi.org/10.3390/s25227006
Vancouver
Sulla-Torres JA, Chavez-Salas NY, Valverde-Riveros MF, Iquira-Becerra DA, Rosas-Paredes K, Cossio-Bolaños MA. Evaluation of Reaction Time and Hand–Eye Coordination in Schoolchildren Using Wearable Sensor-Based Systems: A Study with Neural Trainer Devices. Sensors. 2025. doi:10.3390/s25227006
BibTeX
@article{SullaTorres2025,
author = {Sulla-Torres, José Alfredo and Chavez-Salas, Nadia Yunorvi and Valverde-Riveros, María Fernanda and Iquira-Becerra, Diego Alonso and Rosas-Paredes, Karina and Cossio-Bolaños, Marco Antonio},
title = {Evaluation of Reaction Time and Hand–Eye Coordination in Schoolchildren Using Wearable Sensor-Based Systems: A Study with Neural Trainer Devices},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25227006}
}
EUVIMED