Fachartikel in der Zeitschrift Sensors, online erschienen am 11.11.2025. Verfasst von Andrea Vittimberga und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Information, Electronics and Telecommunication Engineering, Sapienza University of Rome, 00184 Roma, Italy. Hauptthemen laut MEDLINE: Algorithms, Electroencephalography, Seizures, Epilepsy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This paper presents an automated threshold-based multi-channel epileptic seizure detection algorithm designed for low-complexity hardware implementations. The algorithm relies on two discriminative, computationally simple time-domain features, based on power and amplitude variations, that enable accurate and timely detections due to their rapid adaptiveness to fluctuations in neural activity. To ensure long-term functionality and high sensitivity, system thresholds are optimized through an offline calibration process that exploits the statistical analysis of patient-specific inter-ictal and ictal periods. The novelty of the approach lies in its multi-channel decision-making strategy, which enhances reliability against false alarms. The proposed algorithm is tested on multiple datasets to assess its adaptability to different recording conditions, achieving roughly 98% accuracy and over 98% sensitivity on both the EEG CHB-MIT dataset and the iEEG SWEC-ETHZ dataset, with average latencies of 3.37 s and 7.84 s, respectively. These results are comparable to, and in some cases outperform, several published machine-learning-based approaches. On the hardware side, FPGA synthesis highlights the minimal and scalable resource requirements of the proposed architecture, achieved through Time-Division Multiplexing (TDM) of both filtering and feature extraction. When compared to state-of-the-art proposals, the system emerges as an ideal candidate for real-time, resource-constrained hardware implementations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Information, Electronics and Telecommunication Engineering, Sapienza University of Rome, 00184 Roma, Italy.
ORCID-Profile: Giovanni Nicolini, Giuseppe Scotti
Zitieren
APA
Vittimberga, A., Nicolini, G., & Scotti, G. (2025). Real-Time Multi-Channel Epileptic Seizure Detection Exploiting an Ultra-Low-Complexity Algorithm–Hardware Co-Design Approach. Sensors, 25(22), 6889. https://doi.org/10.3390/s25226889
Vancouver
Vittimberga A, Nicolini G, Scotti G. Real-Time Multi-Channel Epileptic Seizure Detection Exploiting an Ultra-Low-Complexity Algorithm–Hardware Co-Design Approach. Sensors. 2025;25(22):6889. doi:10.3390/s25226889
BibTeX
@article{Vittimberga2025,
author = {Vittimberga, Andrea and Nicolini, Giovanni and Scotti, Giuseppe},
title = {Real-Time Multi-Channel Epileptic Seizure Detection Exploiting an Ultra-Low-Complexity Algorithm–Hardware Co-Design Approach},
journal = {Sensors},
year = {2025},
volume = {25},
number = {22},
pages = {6889},
doi = {10.3390/s25226889}
}