Towards Wearable Respiration Monitoring: 1D-CRNN-Based Breathing Detection in Smart Textiles
Sensors · 08.11.2025 · 25 (22) · 6832
DOI: 10.3390/s25226832 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 08.11.2025. Verfasst von Tobias Steinmetzer und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Therapy Sciences (II), Brandenburg University of Technology (BTU) Cottbus-Senftenberg, Platz der Deutschen Einheit 1, 03013 Cottbus, Ge…. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Textiles, Respiration. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Education, Science and Research, German Federal Ministry of Education and Research.
Abstract (Originalsprache)
Monitoring respiratory activity is a key indicator of physiological health and an essential component in smart textile systems for unobtrusive vital sign assessment. In this work, we present a one-dimensional convolutional recurrent neural network (1D-CRNN) for automatic classification of breathing activity from inertial data acquired by a smart e-textile of 59 subjects. The proposed method integrates convolutional layers for local feature extraction with recurrent layers for temporal context modeling, enabling robust segmentation of breathing and noise segments. The model was trained and evaluated using a stratified five-fold cross-validation scheme to account for inter-subject variability and class imbalance. Across different window sizes, the classifier achieved a mean accuracy of 0.88 and an F1-score of 0.92 at a window size of 2000 samples. The best-performing configuration for a single fold, reached an accuracy of 0.995 and an F1-score of 0.99. Furthermore, near-real-time feasibility was demonstrated, with a total processing time—including data loading, classification, segmentation, and visualization—of only 1.76 s for a 250 s measurement, corresponding to more than 100× faster than the recording time. These results indicate that the proposed approach is highly suitable for embedded, on-device inference within wearable systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Therapy Sciences (II), Brandenburg University of Technology (BTU) Cottbus-Senftenberg, Platz der Deutschen Einheit 1, 03013 Cottbus, Germany.
ORCID-Profile: Tobias Steinmetzer
Förderung
- Federal Ministry of Education, Science and Research
- German Federal Ministry of Education and Research
Zitieren
APA
Steinmetzer, T., & Michel, S. (2025). Towards Wearable Respiration Monitoring: 1D-CRNN-Based Breathing Detection in Smart Textiles. Sensors, 25(22), 6832. https://doi.org/10.3390/s25226832
Vancouver
Steinmetzer T, Michel S. Towards Wearable Respiration Monitoring: 1D-CRNN-Based Breathing Detection in Smart Textiles. Sensors. 2025;25(22):6832. doi:10.3390/s25226832
BibTeX
@article{Steinmetzer2025,
author = {Steinmetzer, Tobias and Michel, Sven},
title = {Towards Wearable Respiration Monitoring: 1D-CRNN-Based Breathing Detection in Smart Textiles},
journal = {Sensors},
year = {2025},
volume = {25},
number = {22},
pages = {6832},
doi = {10.3390/s25226832}
}
EUVIMED