EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessment of Elbow Proprioception with Inertial Measurement Units—Validity and Reliability Study

Szymon Stupnicki iD, Grzegorz Mulski iD, Łukasz Żytka iD, Jakub Kaszyński iD, Cezary Baka iD, Bartłomiej Lubiatowski, Przemysław Lubiatowski iD

Sensors · 07.11.2025 · 25 (22) · 6826

DOI: 10.3390/s25226826 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 07.11.2025. Verfasst von Szymon Stupnicki und 6 weiteren Autor:innen. Beteiligte Einrichtung: Rehasport Clinic, 60-201 Poznan, Poland. Hauptthemen laut MEDLINE: Proprioception, Elbow Joint, Elbow. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Inertial measurement units (IMUs) represent a relatively new and promising method for motion analysis. Their main advantages include small size and portability, combined with the use of advanced technologies. To date, few studies have investigated the application of these devices for proprioception assessment, and none have focused specifically on the elbow joint. Therefore, the aim of our study was to assess reliability and validate the protocol of elbow proprioception evaluation using inertial motion sensors.

Methods

Twenty healthy participants underwent active and passive proprioception assessments based on joint position sense (JPS). Two researchers independently performed evaluation. The analyzed data was the error of reproduction of joint position (ERJP). IMU (RSQ Motion sensors) were used for angular joint position assessment and validated against Biodex System 4.

Results

Inter-rater reliability for passive proprioception was good, with a Kendall’s coefficient of 0.77 (p < 0.05) for both RSQ Motion sensors and BIODEX, while active proprioception measured with RSQ Motion sensors showed slightly lower reliability (Kendall’s coefficient of 0.66, p < 0.05). Intra-rater reliability had similar results, with Kendall’s coefficients of 0.74 for passive BIODEX proprioception examination, 0.75 for passive RSQ Motion sensor testing and 0.65 for active proprioception (p < 0.05) measured with RSQ Motion sensors. The Bland–Altman plot revealed an equal distribution of results, which were within the limits of agreement (LoA).

Conclusions

These results suggest proprioception assessment by JPS using inertial motion sensors is reliable and valid. It is an easy to use, light, portable, and inexpensive alternative for proprioception assessment, although further research in diverse clinical settings is needed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProprioceptionElbow JointElbowHumansMaleFemaleAdultReproducibility of ResultsYoung AdultRange of Motion, Articular

Stichwörter der Autor:innen

elbowinertial measurement unitsjoint position sensemotion analysisproprioception

Autor:innen und Institutionen

  • Rehasport Clinic, 60-201 Poznan, Poland.
  • Sport Trauma and Biomechanics Unit, Department of Orthopaedics, Traumatology and Hand Surgery Department, Poznan University of Medical Sciences, 61-545 Poznan, Poland.
  • RSQ Technologies, 61-737 Poznan, Poland.

ORCID-Profile: Szymon Stupnicki, Grzegorz Mulski, Łukasz Żytka, Jakub Kaszyński, Cezary Baka, Przemysław Lubiatowski

Zitieren

APA

Stupnicki, S., Mulski, G., Żytka, Ł., Kaszyński, J., Baka, C., Lubiatowski, B., & Lubiatowski, P. (2025). Assessment of Elbow Proprioception with Inertial Measurement Units—Validity and Reliability Study. Sensors, 25(22), 6826. https://doi.org/10.3390/s25226826

Vancouver

Stupnicki S, Mulski G, Żytka Ł, Kaszyński J, Baka C, Lubiatowski B, et al. Assessment of Elbow Proprioception with Inertial Measurement Units—Validity and Reliability Study. Sensors. 2025;25(22):6826. doi:10.3390/s25226826

BibTeX
@article{Stupnicki2025,
  author = {Stupnicki, Szymon and Mulski, Grzegorz and Żytka, Łukasz and Kaszyński, Jakub and Baka, Cezary and Lubiatowski, Bartłomiej and Lubiatowski, Przemysław},
  title = {Assessment of Elbow Proprioception with Inertial Measurement Units—Validity and Reliability Study},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {22},
  pages = {6826},
  doi = {10.3390/s25226826}
}
Kostenlos starten →