Evaluation of Pre-Applied Conductive Materials in Electrode Grids for Longterm EEG Recording
Sensors · 2025
DOI: 10.3390/s25226810 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Carlos F da Silva Souto und 5 weiteren Autor:innen. Beteiligte Einrichtung: Fraunhofer Institute for Digital Media Technology IDMT, Branch Hearing, Speech and Audio Technology HSA, 26129 Oldenburg, Germany. Hauptthemen laut MEDLINE: Electroencephalography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Oldenburg Branch for Hearing, Speech and Audio Technology HSA is funded in the program »Vorab« by the Lower Saxony Ministry of Science and Culture (MWK) an…, Lower Saxony Ministry of Science and Culture, Volkswagen Foundation.
Abstract (Originalsprache)
Most long-term mobile EEG monitoring systems require professional application of the electrodes, which makes them inconvenient for everyday use. Additionally, many materials that facilitate EEG application, such as dry electrodes, may cause discomfort when worn for longer periods of time. To address these problems, we designed flex-printed EEG electrode grids (trEEGrid) and evaluated signal quality based on two pre-applied conductive materials. Self-applicable trEEGrid patches with a conductive solid hydrogel and a novel silicone-based dry material were used in a day-long (5–6 h) recording session, which included a 4 h continuous recording of impedance levels, as well as two auditory task recordings in the morning and afternoon. The signal-to-noise ratio (SNR) of the auditory evoked potentials (AEPs), AEP morphology, and impedance levels of the conductive materials were compared to evaluate overall signal quality, and further comparisons took place between the morning and afternoon sessions to evaluate signal deterioration over time. Comparable impedance values were observed for both silicone and hydrogel materials, but the silicone material exhibited a higher outlier rate, with impedance values over 200 kΩ. Over time, the impedance values increased for the silicone material and decreased for the hydrogel material. The morphology of the AEP was reproduced comparably well with both materials, with reasonable SNRs in both the morning and the afternoon. In conclusion, when combined with flex-printed electrode grids, silicone and hydrogel materials make it feasible to collect high-quality long-term EEG signals with high wearing comfort.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Fraunhofer Institute for Digital Media Technology IDMT, Branch Hearing, Speech and Audio Technology HSA, 26129 Oldenburg, Germany.
- Neuropsychology Lab, Department of Psychology, University of Oldenburg, 26129 Oldenburg, Germany.
- Cluster of Excellence "Hearing4all", University of Oldenburg, 26129 Oldenburg, Germany.
ORCID-Profile: Karen Insa Wolf
Förderung
- The Oldenburg Branch for Hearing, Speech and Audio Technology HSA is funded in the program »Vorab« by the Lower Saxony Ministry of Science and Culture (MWK) an…
- Lower Saxony Ministry of Science and Culture
- Volkswagen Foundation
Zitieren
APA
da Silva Souto, C. F., Pätzold, W., Scanlon, J. E. M., Winneke, A. H., Debener, S., & Wolf, K. I. (2025). Evaluation of Pre-Applied Conductive Materials in Electrode Grids for Longterm EEG Recording. Sensors. https://doi.org/10.3390/s25226810
Vancouver
da Silva Souto CF, Pätzold W, Scanlon JEM, Winneke AH, Debener S, Wolf KI. Evaluation of Pre-Applied Conductive Materials in Electrode Grids for Longterm EEG Recording. Sensors. 2025. doi:10.3390/s25226810
BibTeX
@article{daSilvaSouto2025,
author = {da Silva Souto, Carlos F and Pätzold, Wiebke and Scanlon, Joanna E M and Winneke, Axel H and Debener, Stefan and Wolf, Karen Insa},
title = {Evaluation of Pre-Applied Conductive Materials in Electrode Grids for Longterm EEG Recording},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25226810}
}
EUVIMED