Enhanced Reaction Time Measurement System Based on 3D Accelerometer in Athletics
Sensors · 2025
DOI: 10.3390/s25216730 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Antonio Pousibet-Garrido und 6 weiteren Autor:innen. Beteiligte Einrichtung: PRIMELab, ECsens, Sport and Health University Research Institute (iMUDS), Department of Electronics and Computer Technology, Research Centre for Info…. Hauptthemen laut MEDLINE: Accelerometry, Reaction Time, Sports, Athletic Performance. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: by Consejo Superior de Deportes (Ministerio de Cultura y Deporte).
Abstract (Originalsprache)
Reaction time (RT) is a key measure of neuromuscular and cognitive performance, but most existing methods rely on laboratory equipment or focus on localized actions such as finger taps or foot lifts, limiting their relevance for whole-body movements. In this work, we present a portable inertial measurement unit (IMU)-based system specifically designed to measure RT during sprint starts. The device integrates a triaxial accelerometer (ICM-20948, ±16 g) and an ESP32 microcontroller, which generates an auditory stimulus, acquires acceleration data at 1 kHz, and computes movement onset in real time. A fixed acceleration threshold, determined from calibration against a high-speed camera reference, was used to detect the first voluntary movement. Both desktop and smartphone applications were implemented to control the system, provide feedback, and store test data. Validation experiments showed good agreement with the high-speed camera used as a reference (R2 = 0.9391), with a mean bias of –1.35 ms and 95% limits of agreement within ±25 ms. The proposed system combines high temporal resolution, portability, and straightforward deployment, enabling reliable assessment of whole-body RT in realistic sports and research environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- PRIMELab, ECsens, Sport and Health University Research Institute (iMUDS), Department of Electronics and Computer Technology, Research Centre for Information and Communications Technologies (CITIC), University of Granada…
- Department of Physical Education, Faculty of Education Sciences, University of Cádiz, 11519 Cádiz, Spain.
ORCID-Profile: Antonio Pousibet-Garrido, Juan A Moreno-Pérez, Pablo Escobedo, Israel Caraballo, José V Gutiérrez-Manzanedo, José L González-Montesinos, Miguel A Carvajal
Förderung
- by Consejo Superior de Deportes (Ministerio de Cultura y Deporte)
Zitieren
APA
Pousibet-Garrido, A., Moreno-Pérez, J. A., Escobedo, P., Caraballo, I., Gutiérrez-Manzanedo, J. V., González-Montesinos, J. L., & Carvajal, M. A. (2025). Enhanced Reaction Time Measurement System Based on 3D Accelerometer in Athletics. Sensors. https://doi.org/10.3390/s25216730
Vancouver
Pousibet-Garrido A, Moreno-Pérez JA, Escobedo P, Caraballo I, Gutiérrez-Manzanedo JV, González-Montesinos JL, et al. Enhanced Reaction Time Measurement System Based on 3D Accelerometer in Athletics. Sensors. 2025. doi:10.3390/s25216730
BibTeX
@article{PousibetGarrido2025,
author = {Pousibet-Garrido, Antonio and Moreno-Pérez, Juan A and Escobedo, Pablo and Caraballo, Israel and Gutiérrez-Manzanedo, José V and González-Montesinos, José L and Carvajal, Miguel A},
title = {Enhanced Reaction Time Measurement System Based on 3D Accelerometer in Athletics},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25216730}
}
EUVIMED