EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY 4.0

A Systematic Review of Wearable Sensors in Rett Syndrome—What Physiological Markers Are Informative for Monitoring Disease States?

Jatinder Singh iD, Georgina Wilkins iD, Athina Manginas, Samiya Chishti, Federico Fiori iD, Girish D Sharma iD, Jay Shetty iD, Paramala Santosh iD

Sensors · 2025

DOI: 10.3390/s25216697 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Sensors, 2025. Verfasst von Jatinder Singh und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Child and Adolescent Psychiatry, Institute of Psychiatry, Psychology and Neuroscience, King's College London, London SE5 8AF, UK. Hauptthemen laut MEDLINE: Rett Syndrome, Wearable Electronic Devices, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 91 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rett syndrome (RTT) presents with a wide range of symptoms spanning various clinical areas. Capturing symptom change as the disorder progresses is challenging. Wearable sensors offer a non-invasive and objective means of monitoring disease states in neurodevelopmental disorders. The goal of this study was to conduct a systematic literature review to critically appraise the literature on the use of wearable sensors in individuals with RTT. The PRISMA criteria were used to search four databases without time restriction and identified 226 records. After removing duplicates, the titles and abstracts of 184 records were screened, 147 were excluded, and 37 were assessed for eligibility. Ten (10) articles remained, and a further two were included after additional searching. In total, 12 articles were included in the final analysis. The sample size ranged from 7 to 47 subjects with an age range of 1 to 41 years. Different wearable biosensor devices were used across studies, with the Empatica E4 wearable device being most frequently used in 33% (4/12) of the studies. All the studies demonstrated a high methodological quality with a low risk of bias. Evidence from wearable sensors, combined with machine learning methods, enabled the prediction of different sleep patterns and clinical severity in RTT. Given the small sample size and the limitations of available data for training machine learning models, we highlight areas for consideration. The review emphasises the need to enhance research on the application of wearable sensors in epilepsy and gastrointestinal manifestations/morbidity in RTT. Increased electrodermal activity (EDA), % of maximum heart rate (HRmax%) and the heart rate to low-frequency power (HR/LF) ratio were identified as physiological measures potentially associated with disease states. Based on the evidence synthesis, the role of physiological parameters and their association with symptom management in RTT is discussed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Rett SyndromeWearable Electronic DevicesBiosensing TechniquesHumansBiomarkersMonitoring, PhysiologicChildChild, PreschoolAdultFemaleAdolescentMachine Learning

Stichwörter der Autor:innen

Rett syndromemultimodal biosensingnon-invasive biosensorsensor integrationwearable sensor

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Department of Child and Adolescent Psychiatry, Institute of Psychiatry, Psychology and Neuroscience, King's College London, London SE5 8AF, UK.
  • Centre for Interventional Paediatric Psychopharmacology and Rare Diseases (CIPPRD), South London and Maudsley NHS Foundation Trust, London SE5 8AZ, UK.
  • Centre for Interventional Paediatric Psychopharmacology (CIPP) Rett Centre, Institute of Psychiatry, Psychology and Neuroscience, King's College London, London SE5 8AF, UK.
  • Rush University, Chicago, IL 60612, USA.
  • Department of Paediatric Neurosciences, Royal Hospital for Children and Young People, Edinburgh Bio Quarter, Edinburgh EH16 4TJ, UK.

ORCID-Profile: Jatinder Singh, Georgina Wilkins, Federico Fiori, Girish D Sharma, Jay Shetty, Paramala Santosh

Zitieren

APA

Singh, J., Wilkins, G., Manginas, A., Chishti, S., Fiori, F., Sharma, G. D., Shetty, J., & Santosh, P. (2025). A Systematic Review of Wearable Sensors in Rett Syndrome—What Physiological Markers Are Informative for Monitoring Disease States?. Sensors. https://doi.org/10.3390/s25216697

Vancouver

Singh J, Wilkins G, Manginas A, Chishti S, Fiori F, Sharma GD, et al. A Systematic Review of Wearable Sensors in Rett Syndrome—What Physiological Markers Are Informative for Monitoring Disease States?. Sensors. 2025. doi:10.3390/s25216697

BibTeX
@article{Singh2025,
  author = {Singh, Jatinder and Wilkins, Georgina and Manginas, Athina and Chishti, Samiya and Fiori, Federico and Sharma, Girish D and Shetty, Jay and Santosh, Paramala},
  title = {A Systematic Review of Wearable Sensors in Rett Syndrome—What Physiological Markers Are Informative for Monitoring Disease States?},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25216697}
}
Kostenlos starten →