EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of Control Algorithms for an Adaptive Running Platform for a Musculoskeletal Rehabilitation System

Artem Obukhov iD, Andrey Volkov iD

Sensors · 2025

DOI: 10.3390/s25216667 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Artem Obukhov und 1 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of VR Simulators, Tambov State Technical University, Tambov 392000, Russia. Hauptthemen laut MEDLINE: Running, Algorithms, Musculoskeletal Diseases. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Higher Education of the Russian Federation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An essential component of modern musculoskeletal rehabilitation systems is treadmills of various sizes, the control of which may rely either on manual adjustment of treadmill speed, fixed for the entire training session, or on automatic regulation based on analysis of the user’s movements and velocity. The aim of this study was to experimentally compare the control functions of an adaptive treadmill designed for musculoskeletal rehabilitation and to assess the influence of the hardware configuration and tracking systems on user stability and the smoothness of transient processes. Two running platforms (of different lengths, one equipped with handrails and one without), two tracking systems (virtual reality trackers and a computer vision system using the MediaPipe Pose model), and three control functions—linear, nonlinear, and proportional-integral-derivative (PID)—were investigated. A set of metrics with both metrical and physiological interpretability was proposed (including positional stability, duration and amplitude of transient processes in position and velocity, subjective assessment, and others), all integrated into a single quality control criterion. This study presents extensive experimental research comparing various designs of adaptive running platforms and tracking systems, exploring the relationships between the available working area length and user comfort, and determining the optimal parameters for the selected control functions. The optimal control function was identified as the linear law for the tracking system based on virtual reality trackers and the PID function for the computer-vision-based tracking system. The conducted experiments made it possible to formulate recommendations regarding the minimum permissible working area length of treadmill platforms and the selection of tracking systems and control functions for musculoskeletal rehabilitation systems. The obtained results are of practical relevance for developing adaptive rehabilitation simulators and creating control algorithms that ensure smooth and stable treadmill motion, thereby enhancing user comfort, efficiency, and safety during musculoskeletal rehabilitation exercises.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RunningAlgorithmsMusculoskeletal DiseasesHumansVirtual Reality

Stichwörter der Autor:innen

adaptive running platformscontrol functionshuman tracking systemsmusculoskeletal rehabilitation

Autor:innen und Institutionen

  • Laboratory of VR Simulators, Tambov State Technical University, Tambov 392000, Russia.

ORCID-Profile: Artem Obukhov, Andrey Volkov

Förderung

  • Ministry of Science and Higher Education of the Russian Federation

Zitieren

APA

Obukhov, A., & Volkov, A. (2025). Development of Control Algorithms for an Adaptive Running Platform for a Musculoskeletal Rehabilitation System. Sensors. https://doi.org/10.3390/s25216667

Vancouver

Obukhov A, Volkov A. Development of Control Algorithms for an Adaptive Running Platform for a Musculoskeletal Rehabilitation System. Sensors. 2025. doi:10.3390/s25216667

BibTeX
@article{Obukhov2025,
  author = {Obukhov, Artem and Volkov, Andrey},
  title = {Development of Control Algorithms for an Adaptive Running Platform for a Musculoskeletal Rehabilitation System},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25216667}
}
Kostenlos starten →