EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Precise Control of Micropipette Flow Rate for Fluorescence Imaging in In Vivo Micromanipulation

Ruimin Li iD, Shaojie Fu iD, Zijian Guo iD, Jinyu Qiu iD, Yuzhu Liu iD, Mengya Liu iD, Qili Zhao iD, Xin Zhao iD

Sensors · 2025

DOI: 10.3390/s25216647 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Ruimin Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Robotics and Automatic Information System, Tianjin Key Laboratory of Intelligent Robotics, Nankai University, Tianjin 300350, China. Hauptthemen laut MEDLINE: Optical Imaging, Micromanipulation, Microinjections. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Tianjin Science and Technology Major Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Precise regulation of micropipette outlet flow is critical for fluorescence imaging in vivo micromanipulations. In such procedures, a micropipette with a micro-sized opening is driven by gas pressure to deliver internal solution into the in vivo environment. The outlet flow rate needs to be precisely regulated to ensure a uniform and stable fluorescence distribution. However, conventional manual pressure injection methods face inherent limitations, including insufficient precision and poor reproducibility. Existing commercial microinjection systems lack a quantitative relationship between pressure and flow rate. And existing calibration methods in the field of microfluidics suffer from a limited flow-rate measurement resolution, constraining the establishment of a precise pressure–flow quantitative relationship. To address these challenges, we developed a closed-loop pressure regulation system with 1 Pa-level control resolution and established a quantitative calibration of the pressure–flow relationship using a droplet-based method. The calibration revealed a linear relationship with a mean pressure–flow gain of 4.846 × 10−17m3·s−1·Pa−1 (R2 > 0.99). Validation results demonstrated that the system achieved the target outlet flow rate with a flow control error less than 10 fL/s. Finally, the application results in brain-slice environment confirmed its capability to maintain stable fluorescence imaging, with fluorescence intensity fluctuations around 1.3%. These results demonstrated that the proposed approach provides stable, precise, and reproducible flow regulation under physiologically relevant conditions, thereby offering a valuable tool for in vivo micromanipulation and detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Optical ImagingMicromanipulationMicroinjectionsAnimalsCalibrationBrainMicrofluidicsPressureMice

Stichwörter der Autor:innen

flow-rate calibrationfluorescence imagingfluorescent dye injectionin vivo manipulationmicropipette flow regulation

Autor:innen und Institutionen

  • Institute of Robotics and Automatic Information System, Tianjin Key Laboratory of Intelligent Robotics, Nankai University, Tianjin 300350, China.
  • Institute of Intelligence Technology and Robotic Systems, Shenzhen Research Institute of Nankai University, Shenzhen 518083, China.
  • National Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, Nankai University, Tianjin 300350, China.

ORCID-Profile: Ruimin Li, Shaojie Fu, Zijian Guo, Jinyu Qiu, Yuzhu Liu, Mengya Liu, Qili Zhao, Xin Zhao

Förderung

  • National Natural Science Foundation of China
  • Tianjin Science and Technology Major Project

Zitieren

APA

Li, R., Fu, S., Guo, Z., Qiu, J., Liu, Y., Liu, M., Zhao, Q., & Zhao, X. (2025). Precise Control of Micropipette Flow Rate for Fluorescence Imaging in In Vivo Micromanipulation. Sensors. https://doi.org/10.3390/s25216647

Vancouver

Li R, Fu S, Guo Z, Qiu J, Liu Y, Liu M, et al. Precise Control of Micropipette Flow Rate for Fluorescence Imaging in In Vivo Micromanipulation. Sensors. 2025. doi:10.3390/s25216647

BibTeX
@article{Li2025,
  author = {Li, Ruimin and Fu, Shaojie and Guo, Zijian and Qiu, Jinyu and Liu, Yuzhu and Liu, Mengya and Zhao, Qili and Zhao, Xin},
  title = {Precise Control of Micropipette Flow Rate for Fluorescence Imaging in In Vivo Micromanipulation},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25216647}
}
Kostenlos starten →