Mechanical Analysis for Active Movement of Upper Limb Rehabilitation Robots to Alleviate Shoulder Pain in Patients with Stroke Hemiplegia and Frozen Shoulder
Sensors · 2025
DOI: 10.3390/s25216644 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Seok Jin Bang und 4 weiteren Autor:innen. Beteiligte Einrichtung: KMAIN Co., Ltd., Seongnam 13517, Republic of Korea. Hauptthemen laut MEDLINE: Hemiplegia, Stroke Rehabilitation, Robotics, Upper Extremity. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Rehabilitation Center, Ministry of Health and Welfare, Republic of Korea, GRRC, TIPS program.
Themen: Schlaganfall
Abstract (Originalsprache)
Shoulder disorders, including frozen shoulder resulting from stroke-induced hemiplegia, significantly reduce a patient’s ability to perform activities of daily living, thereby necessitating repeated rehabilitation. Consequently, extensive research has been conducted on rehabilitation robots to assist in upper-limb motor recovery. The shoulder moves according to the scapulohumeral rhythm. Considering the biomechanical characteristics of the shoulder joint, the rehabilitation robot was designed to replicate a similar kinematic environment using actuators and linkages that emulate the structures of the upper arm, shoulder, and clavicle. To ensure precise operation, the kinematic accuracy of the robot was pre-evaluated. Kinematic analyses were conducted using MATLAB, and the results were compared with coordinate data from the mechanical design to evaluate positional accuracy. In addition, the convergence and accuracy of joint-angle estimation for target positions were analyzed. The forward kinematic analysis revealed that the average positional error between the measured and target coordinates ranged from 0.5% to 2.8%, with the Base Motor–Back Motor segment exhibiting the highest error (2.8%). The inverse kinematic analysis demonstrated stable convergence to the target positions through iterative computations using the Gauss–Newton method, confirming that the actual motion could be accurately reproduced within the designed range of motion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- KMAIN Co., Ltd., Seongnam 13517, Republic of Korea.
- Medical Devices R&D Center, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea.
- Department of Biomedical Engineering, Gachon University College of Medicine, Incheon 21565, Republic of Korea.
- Biohealth & Medical Engineering Major, Gachon University, Seongnam 13120, Republic of Korea.
- Gachon Biomedical & Convergence Institute, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea.
- Department of Health Sciences and Technology, Gachon Advanced Institute for Health & Sciences and Technology (GAIHST), Seongnam 13120, Republic of Korea.
ORCID-Profile: Kwang Gi Kim
Förderung
- National Rehabilitation Center, Ministry of Health and Welfare, Republic of Korea
- GRRC
- TIPS program
- R&D program for rehabilitation research and development funded by the National Rehabilitation Center, Ministry of Health and Welfare, Republic of Korea
- GRRC program of Gyeonggi province
Zitieren
APA
Bang, S. J., Lee, J. S., Song, D. H., Ryu, S. Y., & Kim, K. G. (2025). Mechanical Analysis for Active Movement of Upper Limb Rehabilitation Robots to Alleviate Shoulder Pain in Patients with Stroke Hemiplegia and Frozen Shoulder. Sensors. https://doi.org/10.3390/s25216644
Vancouver
Bang SJ, Lee JS, Song DH, Ryu SY, Kim KG. Mechanical Analysis for Active Movement of Upper Limb Rehabilitation Robots to Alleviate Shoulder Pain in Patients with Stroke Hemiplegia and Frozen Shoulder. Sensors. 2025. doi:10.3390/s25216644
BibTeX
@article{Bang2025,
author = {Bang, Seok Jin and Lee, Jung-Soo and Song, Dong Hyeon and Ryu, Seung Yeob and Kim, Kwang Gi},
title = {Mechanical Analysis for Active Movement of Upper Limb Rehabilitation Robots to Alleviate Shoulder Pain in Patients with Stroke Hemiplegia and Frozen Shoulder},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25216644}
}
EUVIMED