EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Thermal Sensitivity of a Microoptoelectromechanical Evanescent-Coupling-Based Accelerometer

Evgenii Barbin iD, Ivan Kulinich iD, Tamara Nesterenko iD, Alexei Koleda iD, Ayan Myrzakhmetov iD, Denis Mokhovikov iD, Sergey Vtorushin iD, Alena Talovskaia iD

Sensors · 16.10.2025 · 25 (20) · 6388

DOI: 10.3390/s25206388 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 16.10.2025. Verfasst von Evgenii Barbin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Research Institute of Microelectronic Systems, The Tomsk State University of Control Systems and Radioelectronics, 634050 Tomsk, Russia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Higher Education of the Russian Federation, TUSUR Development Program for 2025-2036, as part of the Strategic Academic Leadership Pro-gram, "Priority2030".

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This treatise studies the thermal sensitivity of the mechanical and optical transmission coefficients of a microoptoelectromechanical (MOEM) accelerometer based on evanescent coupling in a temperature range from minus 40 to plus 125 °C. Two types of optical measuring transducers are considered: based on a directional coupler and a resonator. This analysis covers the optical and mechanical components of the thermal sensitivity of the transmission coefficient. In terms of the mechanical part, the temperature effect induces changes to the linear dimensions of the structure and material characteristics and causes internal mechanical stresses as well. The temperature effect on the optical system of the accelerometer is conditioned by the thermo-optic effect of the materials the optical waveguides are made of. This study includes experiments on the refraction index dependence on the temperature of the optical films that compose the optical system of the MOEM accelerometer. The experiment shows that the refraction index of the films grows with temperature and amounts to 0.12642 ppm/°C for silicon nitride on the SiO2/Si substrate. For the optical measuring transducer based on a directional coupler, the thermal sensitivity of the accelerometer’s optical transmission coefficient is 580 ppm/°C. For the resonator-based transducer, the thermal sensitivity is 0.33 °C−1. The thermal sensitivity of the normalized mechanical transmission coefficient of the accelerometer is 120 ppm/°C. For optical measuring transducers based on a directional coupler, the contribution of the temperature dependent refraction index alteration to the overall error is 5 times larger than that of the MOEM accelerometer’s mechanical parameters, while for the resonator-based transducer the difference reaches 3000 times. This means its operability is only possible in a thermostatic environment.

Schlagwörter

Stichwörter der Autor:innen

accelerometercoefficient of thermal expansioncoupling lengthdirectional coupleroptical transducerrefraction indextemperature sensitivitytransmission coefficientwaveguide

Autor:innen und Institutionen

  • Research Institute of Microelectronic Systems, The Tomsk State University of Control Systems and Radioelectronics, 634050 Tomsk, Russia.
  • Laboratory of Radiophotonics, V.E. Zuev Institute of Atmospheric Optics of SB RAS, 634055 Tomsk, Russia.
  • Division for Electronic Engineering, National Research Tomsk Polytechnic University, 634050 Tomsk, Russia.

ORCID-Profile: Evgenii Barbin, Ivan Kulinich, Tamara Nesterenko, Alexei Koleda, Ayan Myrzakhmetov, Denis Mokhovikov, Sergey Vtorushin, Alena Talovskaia

Förderung

  • Ministry of Science and Higher Education of the Russian Federation
  • TUSUR Development Program for 2025-2036, as part of the Strategic Academic Leadership Pro-gram, "Priority2030"

Zitieren

APA

Barbin, E., Kulinich, I., Nesterenko, T., Koleda, A., Myrzakhmetov, A., Mokhovikov, D., Vtorushin, S., & Talovskaia, A. (2025). Thermal Sensitivity of a Microoptoelectromechanical Evanescent-Coupling-Based Accelerometer. Sensors, 25(20), 6388. https://doi.org/10.3390/s25206388

Vancouver

Barbin E, Kulinich I, Nesterenko T, Koleda A, Myrzakhmetov A, Mokhovikov D, et al. Thermal Sensitivity of a Microoptoelectromechanical Evanescent-Coupling-Based Accelerometer. Sensors. 2025;25(20):6388. doi:10.3390/s25206388

BibTeX
@article{Barbin2025,
  author = {Barbin, Evgenii and Kulinich, Ivan and Nesterenko, Tamara and Koleda, Alexei and Myrzakhmetov, Ayan and Mokhovikov, Denis and Vtorushin, Sergey and Talovskaia, Alena},
  title = {Thermal Sensitivity of a Microoptoelectromechanical Evanescent-Coupling-Based Accelerometer},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {20},
  pages = {6388},
  doi = {10.3390/s25206388}
}