Assessment of Gait and Balance in Elderly Individuals with Knee Osteoarthritis Using Inertial Measurement Units
Sensors · 2025
DOI: 10.3390/s25206288 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Lin-Yen Cheng und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Medicine and Rehabilitation, Cheng Hsin General Hospital, Taipei 112, Taiwan. Hauptthemen laut MEDLINE: Osteoarthritis, Knee, Postural Balance, Gait. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Technology of Taiwan, National Science and Technology Council of Taiwan, Cheng Hsin General Hospital.
Abstract (Originalsprache)
Knee osteoarthritis (OA) is a prevalent condition in older adults that often results in impaired gait and balance, increased risk of falls, and reduced quality of life. Conventional clinical assessments may not adequately capture these deficiencies. This study investigated the gait and balance of elderly individuals with knee OA using wearable inertial measurement units (IMUs). Forty-four participants with Kellgren–Lawrence grade 2–3 knee OA (71.23 ± 5.75 years) and forty-five age-matched controls (70.87 ± 4.30 years) completed dynamic balance (balance board), static balance (single-leg stance), ‘timed up and go’ (TUG), and normal walking tasks. Between 2 and 8 IMUs, depending on the task, were placed on the head, chest, waist, knees, ankles, soles, and balance board to record kinematic data. Balance was quantified using absolute angular velocity and linear acceleration, with group differences analyzed by MANOVA and Bonferroni-adjusted univariate tests. The participants with knee OA exhibited greater gait asymmetry, although the difference was not significant. However, they consistently demonstrated higher absolute angular velocities than controls across most body segments during static and dynamic tasks, indicating reduced postural stability. No group differences were observed in TUG performance. These findings suggest that IMU-based measures, particularly angular velocity, are sensitive to balance impairment detection in knee OA. Incorporating IMU technology into clinical assessments may facilitate early identification of instability and guide targeted interventions to reduce fall risk.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physical Medicine and Rehabilitation, Cheng Hsin General Hospital, Taipei 112, Taiwan.
- Department of Mechanical Engineering, National Taiwan University, Taipei 106, Taiwan.
- Department of Physiology and Biophysics, National Defense Medical Center, Taipei 114, Taiwan.
ORCID-Profile: Fu-Cheng Wang
Förderung
- Ministry of Science and Technology of Taiwan
- National Science and Technology Council of Taiwan
- Cheng Hsin General Hospital
- Ministry of Science and Technology (MOST), Taiwan
- the National Science and Technology Council (NSTC), Taiwan
- Cheng Hsin General Hospital, Taiwan
Zitieren
APA
Cheng, L. Y., Chien, Y. C., Lin, T. T., Lin, J. Y., Cheng, H. T., Chang, C. W., Chen, S. F., & Wang, F. C. (2025). Assessment of Gait and Balance in Elderly Individuals with Knee Osteoarthritis Using Inertial Measurement Units. Sensors. https://doi.org/10.3390/s25206288
Vancouver
Cheng LY, Chien YC, Lin TT, Lin JY, Cheng HT, Chang CW, et al. Assessment of Gait and Balance in Elderly Individuals with Knee Osteoarthritis Using Inertial Measurement Units. Sensors. 2025. doi:10.3390/s25206288
BibTeX
@article{Cheng2025,
author = {Cheng, Lin-Yen and Chien, Yen-Chang and Lin, Tzu-Tung and Lin, Jou-Yu and Cheng, Hsin-Ti and Chang, Chia-Wei and Chen, Szu-Fu and Wang, Fu-Cheng},
title = {Assessment of Gait and Balance in Elderly Individuals with Knee Osteoarthritis Using Inertial Measurement Units},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25206288}
}
EUVIMED