EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Muscle Strength Estimation of Key Muscle–Tendon Units During Human Motion Using ICA-Enhanced sEMG Signals and BP Neural Network Modeling

Hongyan Liu iD, Jongchul Park iD, Junghee Lee, Dandan Wang

Sensors · 2025

DOI: 10.3390/s25206273 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Hongyan Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Marine Convergence Design Engineering, Pukyong National University, 45, Yongso-ro, Nam-gu, Busan 48513, Republic of Korea. Hauptthemen laut MEDLINE: Tendons, Neural Networks, Computer, Muscle Strength, Electromyography. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This work was supported by a grant from the Brain Korea 21 Program for Leading Universities and Students (BK21 FOUR) MADEC Marine Design Engineering Education…, MADEC Marine Design Engineering Education Research Group.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurately predicting the muscle strength of key muscle–tendon units during human motion is vital for understanding movement mechanisms, optimizing exercise training, evaluating rehabilitation progress, and advancing prosthetic control technologies. Traditional prediction methods often suffer from low accuracy and high computational complexity. To address these challenges, this study employs independent component analysis (ICA) to predict the muscle strength of tendon units in primary moving parts of the human body. The proposed method had the highest accuracy in localization, at 98% when the sample size was 20. When the sample size was 100, the proposed method had the shortest localization time, with a localization time of 0.025 s. The accuracy of muscle strength prediction based on backpropagation neural network for key muscle–tendon units in human motion was the highest, with an accuracy of 99% when the sample size was 100. The method can effectively optimize the accuracy and efficiency of muscle strength prediction for key muscle–tendon units in human motion and reduce computational complexity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TendonsNeural Networks, ComputerMuscle StrengthElectromyographyMuscle, SkeletalHumansMovementMaleAlgorithmsAdultMotion

Stichwörter der Autor:innen

BPPCCindependent component analysis algorithmmuscle strength predictionmuscle–tendon unit

Autor:innen und Institutionen

  • Department of Marine Convergence Design Engineering, Pukyong National University, 45, Yongso-ro, Nam-gu, Busan 48513, Republic of Korea.

ORCID-Profile: Hongyan Liu, Jongchul Park

Förderung

  • This work was supported by a grant from the Brain Korea 21 Program for Leading Universities and Students (BK21 FOUR) MADEC Marine Design Engineering Education…
  • MADEC Marine Design Engineering Education Research Group

Zitieren

APA

Liu, H., Park, J., Lee, J., & Wang, D. (2025). Muscle Strength Estimation of Key Muscle–Tendon Units During Human Motion Using ICA-Enhanced sEMG Signals and BP Neural Network Modeling. Sensors. https://doi.org/10.3390/s25206273

Vancouver

Liu H, Park J, Lee J, Wang D. Muscle Strength Estimation of Key Muscle–Tendon Units During Human Motion Using ICA-Enhanced sEMG Signals and BP Neural Network Modeling. Sensors. 2025. doi:10.3390/s25206273

BibTeX
@article{Liu2025,
  author = {Liu, Hongyan and Park, Jongchul and Lee, Junghee and Wang, Dandan},
  title = {Muscle Strength Estimation of Key Muscle–Tendon Units During Human Motion Using ICA-Enhanced sEMG Signals and BP Neural Network Modeling},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25206273}
}
Kostenlos starten →