EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enhanced Design and Characterization of a Wearable IMU for High-Frequency Motion Capture

Diego Valdés-Tirado iD, Gonzalo García Carro iD, Juan C Alvarez iD, Diego Álvarez iD, Antonio López iD

Sensors · 2025

DOI: 10.3390/s25196224 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Diego Valdés-Tirado und 4 weiteren Autor:innen. Beteiligte Einrichtung: Multisensor Systems and Robotics Group (SiMuR), Department of Electrical, Electronic, Communications and Systems Engineering, University of Oviedo, 3…. Hauptthemen laut MEDLINE: Wearable Electronic Devices. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents the third-generation design of Bimu, a compact wearable inertial measurement unit (IMU) tailored for advanced human motion tracking. Building on prior iterations, Bimu R2 focuses on enhancing thermal stability, data integrity, and energy efficiency by integrating onboard memory, redesigning the power management system, and optimizing the communication interfaces. A detailed performance evaluation—including noise, bias, scale factor, power consumption, and drift—demonstrates the device’s reliability and readiness for deployment in real-world applications ranging from clinical gait analysis to high-speed motion capture. The improvements introduced offer valuable insights for researchers and engineers developing robust wearable sensing solutions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesHumansEquipment DesignMotionMovementGaitMotion Capture

Stichwörter der Autor:innen

embedded systemsenergy efficiencygait analysisinertial sensorssignal characterizationwearable IMU

Autor:innen und Institutionen

  • Multisensor Systems and Robotics Group (SiMuR), Department of Electrical, Electronic, Communications and Systems Engineering, University of Oviedo, 33204 Gijón, Spain.

ORCID-Profile: Diego Valdés-Tirado, Gonzalo García Carro, Juan C Alvarez, Diego Álvarez, Antonio López

Zitieren

APA

Valdés-Tirado, D., Carro, G. G., Alvarez, J. C., Álvarez, D., & López, A. (2025). Enhanced Design and Characterization of a Wearable IMU for High-Frequency Motion Capture. Sensors. https://doi.org/10.3390/s25196224

Vancouver

Valdés-Tirado D, Carro GG, Alvarez JC, Álvarez D, López A. Enhanced Design and Characterization of a Wearable IMU for High-Frequency Motion Capture. Sensors. 2025. doi:10.3390/s25196224

BibTeX
@article{ValdsTirado2025,
  author = {Valdés-Tirado, Diego and Carro, Gonzalo García and Alvarez, Juan C and Álvarez, Diego and López, Antonio},
  title = {Enhanced Design and Characterization of a Wearable IMU for High-Frequency Motion Capture},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25196224}
}
Kostenlos starten →