EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Novel Whole-Body Wearable Technology for Motor Assessment in Multiple Sclerosis: Feasibility and Usability Pilot Study

Jessica Podda iD, Erica Grange iD, Claudia Latella iD, Andrea Tacchino iD, Enrico Valli iD, Ludovica Danovaro, Gianluca Milani iD, Marco Forleo, Antonella Tatarelli iD, Davide Gorbani iD, Alex Coppola iD, Ludovico Pedullà und 2 weitere

Sensors · 2025

DOI: 10.3390/s25196214 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Jessica Podda und 13 weiteren Autor:innen. Beteiligte Einrichtung: neuroBRITE Research Center, Italian Multiple Sclerosis Foundation, 16149 Genoa, Italy. Hauptthemen laut MEDLINE: Multiple Sclerosis, Wearable Electronic Devices. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the European Union - NextGenerationEU and the Ministry of University and Research (MUR). National Recovery and Resilience Plan (NRRP), Mission 4, Component 2,…, European Union—NextGenerationEU and by the Ministry of University and Research (MUR), National Recovery and Resilience Plan (NRRP), Mission 4, Component 2, Inv….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

(1)

Background

Technological advancements provide new opportunities to objectively assess motor deficits in people with Multiple Sclerosis (PwMS). This pilot study aimed to evaluate the performance and usability of iFeel, a novel wearable system which integrates inertial sensors, instrumented shoes, and an AI-based algorithm. (2)

Methods

Sixteen adult PwMS (Expanded Disability Status Scale—EDSS ≤ 6) performed motor tests (Timed 25-Foot Walk—T25FW; Timed Up and Go—TUG) both with and without the iFeel suit. Patient-reported outcomes (PROs) were also collected to assess perceived fatigue, dual-task impact, and walking difficulties. System Usability Scale (SUS) and ad hoc questionnaires have been further administered to test usability. (3)

Results

No significant differences were found between the clinician and system-based scores for both T25FW (p = 0.383) and TUG (p = 0.447). Reliability analyses showed good agreement for T25FW (Intraclass Correlation Coefficient—ICC = 0.83) and excellent agreement for TUG (ICC = 0.92). Sensor-derived measures correlated strongly with PROs on fatigue, dual-task interference, and mobility. Usability was rated high (SUS: 78.6 ± 16.1), with participants reporting minimal discomfort and positive perceptions of iFeel usefulness for rehabilitation, health monitoring, and daily activities. (4)

Conclusions

This pilot study provides preliminary yet promising evidence on the feasibility, usability, and perceived usefulness of the iFeel technology for motor assessment in PwMS. The findings support its further development and potential integration into clinical practice, particularly for remote or continuous motor monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Multiple SclerosisWearable Electronic DevicesHumansPilot ProjectsMaleFemaleMiddle AgedAdultFeasibility StudiesFatigueAlgorithms

Stichwörter der Autor:innen

AImotor assessmentmultiple sclerosisusabilitywearable sensorwearable technology

Autor:innen und Institutionen

  • neuroBRITE Research Center, Italian Multiple Sclerosis Foundation, 16149 Genoa, Italy.
  • Artificial and Mechanical Intelligence laboratory, Italian Institute of Technology, 16163 Genoa, Italy.

ORCID-Profile: Jessica Podda, Erica Grange, Claudia Latella, Andrea Tacchino, Enrico Valli, Gianluca Milani, Antonella Tatarelli, Davide Gorbani, Alex Coppola, Giampaolo Brichetto

Förderung

  • the European Union - NextGenerationEU and the Ministry of University and Research (MUR). National Recovery and Resilience Plan (NRRP), Mission 4, Component 2,…
  • European Union—NextGenerationEU and by the Ministry of University and Research (MUR), National Recovery and Resilience Plan (NRRP), Mission 4, Component 2, Inv…

Zitieren

APA

Podda, J., Grange, E., Latella, C., Tacchino, A., Valli, E., Danovaro, L., Milani, G., Forleo, M., Tatarelli, A., Gorbani, D., Coppola, A., Pedullà, L., Brichetto, G., & Pucci, D. (2025). A Novel Whole-Body Wearable Technology for Motor Assessment in Multiple Sclerosis: Feasibility and Usability Pilot Study. Sensors. https://doi.org/10.3390/s25196214

Vancouver

Podda J, Grange E, Latella C, Tacchino A, Valli E, Danovaro L, et al. A Novel Whole-Body Wearable Technology for Motor Assessment in Multiple Sclerosis: Feasibility and Usability Pilot Study. Sensors. 2025. doi:10.3390/s25196214

BibTeX
@article{Podda2025,
  author = {Podda, Jessica and Grange, Erica and Latella, Claudia and Tacchino, Andrea and Valli, Enrico and Danovaro, Ludovica and Milani, Gianluca and Forleo, Marco and Tatarelli, Antonella and Gorbani, Davide and Coppola, Alex and Pedullà, Ludovico and Brichetto, Giampaolo and Pucci, Daniele},
  title = {A Novel Whole-Body Wearable Technology for Motor Assessment in Multiple Sclerosis: Feasibility and Usability Pilot Study},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25196214}
}
Kostenlos starten →