Electronic Noise Measurement of a Magnetoresistive Sensor: A Comparative Study
Sensors · 06.10.2025 · 25 (19) · 6182
DOI: 10.3390/s25196182 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.10.2025. Verfasst von Cristina Davidaș und 5 weiteren Autor:innen. Beteiligte Einrichtung: Applied Electronics Department, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Unitatea Executiva Pentru Finantarea Invatamantului Superior a Cercetarii Dezvoltarii si Inovarii, MRID-CNCS-UEFISCDI, PNCDI IV.
Abstract (Originalsprache)
The intrinsic noise of giant magnetoresistive (GMR) sensors is large at low frequencies, and their resolution is inevitably significantly limited. Investigation of GMR noise requires the use of measurement systems that have lower noise than the sample. In this context, the main purpose of this study is to evaluate the effectiveness of two electronic noise measurement configurations of a single GMR sensing element. The first method connects the sample in a voltage divider configuration and the second method connects in a Wheatstone bridge configuration. Three amplification set-ups were investigated: a low-noise amplifier, an ultra-low-noise amplifier and an instrumentation amplifier. Using cross-correlation, the noise of the measurement system introduced by the amplifiers was reduced. Noise spectra were recorded at room temperature in the frequency range of 0.5 Hz to 10 kHz, under different sample bias voltages. The measurements were performed in zero applied magnetic field and in a field corresponding to the maximum sensitivity of the sensor. From the noise spectra, the detectivity of the sensor was determined to be in the 200–300 nT/√Hz range. Good agreement was observed between the results obtained using all three set-ups, suggesting the effectiveness of the noise measurement systems applied to the magnetoresistive sensor.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Applied Electronics Department, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.
- Centre for Superconductivity, Spintronics and Surface Science, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.
- European University of Technology, European Union.
- Physics and Chemistry Department, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.
- EUt+ Institute of Nanomaterials & Nanotechnologies-EUTINN, European University of Technology, European Union.
ORCID-Profile: Liviu Marin Viman, Ovidiu Aurel Pop
Förderung
- Unitatea Executiva Pentru Finantarea Invatamantului Superior a Cercetarii Dezvoltarii si Inovarii
- MRID-CNCS-UEFISCDI
- PNCDI IV
Zitieren
APA
Davidaș, C., Ștețco, E. M., Viman, L. M., Gabor, M. S., Pop, O. A., & Petrișor, T. (2025). Electronic Noise Measurement of a Magnetoresistive Sensor: A Comparative Study. Sensors, 25(19), 6182. https://doi.org/10.3390/s25196182
Vancouver
Davidaș C, Ștețco EM, Viman LM, Gabor MS, Pop OA, Petrișor T. Electronic Noise Measurement of a Magnetoresistive Sensor: A Comparative Study. Sensors. 2025;25(19):6182. doi:10.3390/s25196182
BibTeX
@article{Davida2025,
author = {Davidaș, Cristina and Ștețco, Elena Mirela and Viman, Liviu Marin and Gabor, Mihai Sebastian and Pop, Ovidiu Aurel and Petrișor, Traian},
title = {Electronic Noise Measurement of a Magnetoresistive Sensor: A Comparative Study},
journal = {Sensors},
year = {2025},
volume = {25},
number = {19},
pages = {6182},
doi = {10.3390/s25196182}
}