EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Novel TMR Cantilever-Based Bi-Directional Flow Sensor for Agricultural and Domestic Applications

Anwar Ulla Khan iD, Ateyah Alzahrani iD

Sensors · 22.09.2025 · 25 (18) · 5915

DOI: 10.3390/s25185915 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 22.09.2025. Verfasst von Anwar Ulla Khan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering Technology, College of Applied Industrial Technology, Jazan University, Jazan 45142, Saudi Arabia. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article introduces a novel, cost-effective, noninvasive sensing mechanism for measuring water flow rate. It employs two tunneling magnetoresistance (TMR) sensors (analog and bi-polar), a magnet, and a stainless-steel cantilever. The TMR sensors are installed outside the insulating water pipe. A magnet is fixed at the free end of the cantilever and integrated into the pipe system. The cantilever’s deflection corresponds to the flow rate, with an analog TMR sensor measuring the bending angle. This bending angle, in either direction of the cantilever’s deflection, is captured through the analog voltage from the TMR sensor. The output from the analog TMR sensor is an analog voltage that directly reflects the strength of the magnetic field. An ESP32 microcontroller records the voltage from the analog TMR sensor, converts it to flow rates, and utilizes the bi-polar TMR sensor to ascertain the flow direction. A prototype sensor was developed and tested in a laboratory-scale setup to validate the effectiveness of the sensing mechanism. This prototype demonstrated a worst-case accuracy of 1.0% across flow rates of 0 to 1.5 m3/h for both the forward and reverse flow directions. The response and recovery times of the sensor are approximately 470 ms and 592 ms for forward and 487 ms and 625 ms for reverse direction flow. Also, hysteresis errors of 1.84% and 2.06% have been calculated for both flow directions. Notably, the sensing element does not contain any rotating components or require electrical connections to the cantilever for measurement. These attributes potentially lead to lower maintenance requirements and a longer lifespan for the sensor.

Schlagwörter

Stichwörter der Autor:innen

ESP32 boardTMR sensorcantileverflow measurementnoninvasive measurement

Autor:innen und Institutionen

  • Department of Electrical Engineering Technology, College of Applied Industrial Technology, Jazan University, Jazan 45142, Saudi Arabia.
  • Department of Mechanical and Industrial Engineering, College of Engineering and Computing in Al-Qunfudhah, Umm Al-Qura University, Makkah 24381, Saudi Arabia.

ORCID-Profile: Anwar Ulla Khan, Ateyah Alzahrani

Zitieren

APA

Khan, A. U., & Alzahrani, A. (2025). A Novel TMR Cantilever-Based Bi-Directional Flow Sensor for Agricultural and Domestic Applications. Sensors, 25(18), 5915. https://doi.org/10.3390/s25185915

Vancouver

Khan AU, Alzahrani A. A Novel TMR Cantilever-Based Bi-Directional Flow Sensor for Agricultural and Domestic Applications. Sensors. 2025;25(18):5915. doi:10.3390/s25185915

BibTeX
@article{Khan2025,
  author = {Khan, Anwar Ulla and Alzahrani, Ateyah},
  title = {A Novel TMR Cantilever-Based Bi-Directional Flow Sensor for Agricultural and Domestic Applications},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {18},
  pages = {5915},
  doi = {10.3390/s25185915}
}