Fachartikel in der Zeitschrift Sensors, online erschienen am 20.09.2025. Verfasst von Boran Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin 150001, China. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Touyan Innovation Program of Heilongjiang Province, China.
Abstract (Originalsprache)
Based on the energy equation of the hemispherical resonator, this study analyzes the influence of ion beam balancing on the frequency split of the hemispherical resonator. Firstly, the formula for mass defects and the resonant frequency of the resonator is obtained through the energy equation. All mass defects of the resonator are equivalent to fourth harmonic wall thickness defects. The quantitative relationship between harmonic wall thickness defects and the resonant frequency and the geometric relationship between the heavy axis of the resonator and the distribution of mass defects are determined. Secondly, the balancing function is introduced into the resonant frequency equation of the hemispherical resonator, and a mathematical model is established for the resonant frequency, defect wall thickness, and balancing depth of the hemispherical resonator. By introducing relevant errors, the impact of balancing errors on the frequency characteristics of the hemispherical resonator is calculated. Finally, an ion beam balancing experiment is designed to verify the effectiveness of the theory. The results show that the frequency split can be better than 0.001 Hz after balancing, effectively improving the hemispherical resonator’s performance.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin 150001, China.
- The 26th Institute of China Electronics Technology Group Corporation, Chongqing 400600, China.
ORCID-Profile: Boran Li
Förderung
- Touyan Innovation Program of Heilongjiang Province, China
Zitieren
APA
Li, B., Wang, C., & Fang, Z. (2025). Effect of Ion Beam Balancing on Frequency Split for Fourth Harmonic Mass Defect of Hemispherical Resonator. Sensors, 25(18), 5888. https://doi.org/10.3390/s25185888
Vancouver
Li B, Wang C, Fang Z. Effect of Ion Beam Balancing on Frequency Split for Fourth Harmonic Mass Defect of Hemispherical Resonator. Sensors. 2025;25(18):5888. doi:10.3390/s25185888
BibTeX
@article{Li2025,
author = {Li, Boran and Wang, Changhong and Fang, Zhen},
title = {Effect of Ion Beam Balancing on Frequency Split for Fourth Harmonic Mass Defect of Hemispherical Resonator},
journal = {Sensors},
year = {2025},
volume = {25},
number = {18},
pages = {5888},
doi = {10.3390/s25185888}
}
EUVIMED